- 32 -
( only if
is different from 0)
(from 0 to max full scale; default: 0): this parameter indicates the limit within which the
automatic fall is updated according to the parameter
.By setting a low value is obtained
more accurately but the length of the batchings could increase, because, if necessary, the
AUTOMATIC fall is updated every cycle regardless of
. By setting 0, the function is
disabled.
Example
: By setting
= 3,
= 5 and the weight equal to 100, the instrument updates
the fall every batching, until the batched weight falls within the 95 to 105 range, and then it goes
back to update the AUTOMATIC fall every 3 batchings.
(from 0 to maximum weight; default: 0): in this parameter it is possible to set the fall value for
each formula (only if
= 0) or to display and/or to modify the fall value calculated
automatically by the instrument (only if
is different from 0).
TOLERANCE
(from 0 to maximum weight; default: 0): Adjustable parameter for each formula that defines how
much the batched weight value can deviate from the one set in formula. If the batched weight is
higher or lower than the amount to be batched, for a value greater than the tolerance, the instrument
closes the TOLERANCE contact. Press ENTER to continue the batching; the TOLERANCE contact
remains closed until the weight reaches the minimum weight value and the safe emptying time has
elapsed. Example: if a SET = 1000 value is set and a TOLERANCE = 100 value is set, the batched
weight must not be lower than 900 or higher than 1100
to allow the instrument to continue the
batching process. By setting 0, the function is disabled.
SLOW
(from 0 to maximum weight; default: 0): single valid value for all the formulas in place of the
preset value. When the weight has reached the SET value minus the value set in this parameter, the
slow batching phase starts by the PRESET contact. If the set value is greater than the weight to
batch, the batching will be in slow phase. By setting 0, the function is disabled.
Example
: If SET = 100 and SLOW = 15, the slow phase begins when the weight reaches 85.
TAPPING FUNCTION
In the event that the batching instrument is not equipped with the speed “slow” it is possible to use
this function to slow down the product batching in the final phase (through opening and closing
cycles of the SET contact) and to increase the accuracy. Set in
parameter the product
amount you want to batch with the tapping function enabled.