OPERATION SETTINGS
:
Select the switch conditions from the SET opening to the CYCLE END closing.
-
(default:
): time set in constants (
).
-
(default:
): START input closure or ENTER key pressure.
-
(default:
): stable weight.
(default:
):
Select the operating mode of
SET and PRESET contacts.
-
=
: at the batching start, only the PRESET contact is closed; once reached the preset
set value, the related contact is opened and the SET contact is closed; reached the final
value of set, the related contact is opened.
-
=
: at the batching start, the SET and PRESET contacts are closed simultaneously;
once reached the preset value, the related contact is opened (beginning of the slow phase);
once reached the set value, also the related contact is opened. For single-speed batching,
program
=
and use only the SET contact.
-
=
: at the batching start, only the PRESET contact is closed; once reached the preset
value, also the SET contact is closed; once reached the final value of set, both are reopened.
(default:
)
:
Select the display type of net / gross weight during the CYCLE END phase
(unloading of the scale at the end of batching).
-
: during the cycle end, the net weight is displayed. After the CYCLE END opening, the
gross weight is displayed.
-
: during the cycle end, the gross weight is displayed.
(default:
)
:
Select the batching resume mode
after a power failure.
-
: (Automatic) at the power restore,
appears for 3 seconds, after which the
batching resumes from the point of interruption.
-
:
(Manual)
at the power restore
appears, press ENTER to resume the batching
or press ESC to stop it.
INFO MENU
: active options are displayed.
+
+