- 28 -
ALARM RELAY CLOSURE
The ALARM relay closing can be enabled or disabled for each of the following alarms: approval
contact (
);formula not programmed (
); maximum weight exceeded (
);
minimum weight (
); no increase in weight (
); no decrease in weight (
); fall
(
); the PC did not read the batching data (
).
: in presence of alarm, the relay is closed (default)
: the relay is not closed even in the presence of alarm
TEST
-
Input Test:
: ensure that for each open input
is displayed,
is displayed when the input is closed.
-
Output Test:
: setting
ensure that the corresponding output opens. Setting
ensure that the
corresponding output closes.
-
E/EC Option Test:
: It shows the formula selected by the E/EC option, if the option is not present or is not
active, the message
is displayed.
-
Analog Output Option Test:
: It allows the analog signal to range between the minimum and the maximum values
starting from the minimum.
: current output test.
: voltage output test.
-
Millivolt Test:
: displays the load cell response signal in mV with four decimals.
DATE AND TIME SETTING
Selecting the
item in the main menu, access is obtained to the date and time display menu.
Pressing ENTER several times scrolls through days - months – years and hours – minutes; pressing
◄ selects the figure to modify; pressing ▲ the figure increases; pressing ENTER you can confirm
and go to the next menu item.
+
+
+