- 33 -
COMMUNICATION INTERFACE
WRITING
READING
Write the value in W1.
Send command 1007 to CMDR.
Send command 1006 to CMDR.
Read the value in R1.
NO COMPARISON TIME
(from 0.0 to 999.9 seconds; default: 0.0): this is the instrument waiting time during batching,
after the opening of PRESET, before comparing the weight with the programmed SET value.
COMMUNICATION INTERFACE
WRITING
READING
Write the value in W1.
Send command 1097 to CMDR.
Send command 1096 to CMDR.
Read the value in R1.
NO PRODUCT LOAD TIME
(from 0.0 to 999.9 seconds; default: 0.0): this parameter allows the product control during
batching. if there is no product load, the instrument waits for a set duration of time before activating
the alarm
.
COMMUNICATION INTERFACE
WRITING
READING
Write the value in W1.
Send command 1033 to CMDR.
Send command 1032 to CMDR.
Read the value in R1.
NO PRODUCT UNLOAD TIME
(from 0.0 to 999.9 seconds; default: 0.0): this parameter allows the product control during
the unloading phase (cycle end). If there is no product extraction, the instrument waits for a set
duration of time before activating the alarm
.
WARNING:
The control is only actuated after unloading of the product has started (the weight must
decrease by at least 10 divisions).
COMMUNICATION INTERFACE
WRITING
READING
Write the value in W1.
Send command 1035 to CMDR.
Send command 1034 to CMDR.
Read the value in R1.