LATNEX MF-30K User Manual Download Page 1

MF-30K

AC/DC Electromagnets and

Permanent Magnets Gauss Meter

User’s Manual

HB4MF30K0000

®

Summary of Contents for MF-30K

Page 1: ...MF 30K AC DC Electromagnets and Permanent Magnets Gauss Meter User s Manual HB4MF30K0000...

Page 2: ...6 5 6 Auto Record 6 5 7 Read the record data from RAM 7 5 8 Data Hold 7 5 9 The Max Min Values Hold 7 5 10 Disable Auto Power Off Function 7 5 11 Stopping buzzer 7 5 12 Manual range mode Automatic ra...

Page 3: ...the stress after processing of stainless material Measurement for the magnetic force of magnetic materials Measurement for the various steel materials with natural magnetism Measurement for the magnet...

Page 4: ...ammable gas or humid environments Operating altitude up to 2000M Operating environment Indoor use Pollution degree 2 Clean with soft cloth when dirty such as glasses cloth Do not clean with chemicals...

Page 5: ...rom RAM R M Left 6 Set to Zero Zero Relative Value REL 7 AC DC switch Up 8 Manual range mode Automatic range mode 9 Manual record REC Auto record LOG 10 Buzzer GO NO GO 11 The max min value hold Down...

Page 6: ...ng Please refer to Fig 1 4 Read the measured value from the LCD display 5 Cover the cap of probe back If the probe not inserted into the host or not inserted completely will appear Please turn power o...

Page 7: ...eroing the value in measuring from HOST The zeroing function is unavailable for temperature 5 2 Peak Measurement Move the probe away from the magnetic field then press and hold for 2 seconds to start...

Page 8: ...rn the backlight on or off If connected via an external power supply the backlight will lit automatically and stay on The backlight will automatically turn off after being lit for 30 seconds 5 5 Manua...

Page 9: ...on again press to show the MAX and MIN values by turns Press and hold to quit The measured data can be held and updated as the measured the MAX and MIN values 5 10 Disable Auto Power Off Function With...

Page 10: ...t between AC magnetic field and DC magnetic field 5 14Setup Step 1 Step 8 Press to enter the setup procedure from step 1 to step 8 while flashes on the LCD Step 1 Setup unit G or mT 1 Press or to sele...

Page 11: ...2 Again press to go to Step 6 Step 6 Setup year month date 1 Go to the mode to setup the year month date 2 Press or to select the item to modify the digits of the selected item will flash 3 Then pres...

Page 12: ...ss to return to the measurement mode and clear the record while LCD shows CLEAR 6 Software Installation Windows 7 Windows 10 operating systems Place the CD included with this meter into the CD DVD ROM...

Page 13: ...MF 30K 11 Execute the PC desktop software program Double click the left mouse button on the desktop program Thermometer Meter to execute the desktop program...

Page 14: ...with Automatic Measurement Conversion of units 1mT milli Tesla 10G Gauss Relative value Peak hold Real time Zeroing function Enable and disable auto power off function default power off is 15 minutes...

Page 15: ...y 5 C to 40 C 41 F to 104 F 80 RH Storage temperature and humidity 0 C to 50 C relative humidity under 70 Weight Approximately 320 grams with battery Dimensions 156 L x 73 W x 35 H mm AC to DC Adaptor...

Page 16: ...tion Accuracy DC milli Tesla 300 00 mT 0 01 mT 4 10dgt 2000 0 mT 0 1 mT 2000 1 3000 0 mT 0 1 mT N A DC Gauss 3000 0G 0 1G 4 10dgt 20 000G 1G 20 001 30 000 G 1G N A AC milli Tesla 150 00mT 0 01 mT 5 20...

Page 17: ...ot used for a long period of time in order to prevent battery leakage and causing damages to internal components 4 When the instrument failure only by the authorized service provider or return the ori...

Page 18: ......

Page 19: ...EMR Shielding Solutions Inc 399 Four Valley Drive Unit 13 Concord Ontario L4K 5Y7 Canada E mail info emrshieldingsolutions com www emrshieldingsolutions com...