22
45
44
9. SPECIFICATIONS
Clock accuracy
Calendar
Printing system
Dimensions
Weight
Rating
Power failure
compensation
Print at power
failure
Memory capacity
Operating
environment
Monthly accuracy
±
15s (at ordinary temperature)
Year up to 2099. Automatically adjusted to leap years, 31-day
months and months with thirty or fewer days, and the days of the
week.
Dot matrix
Three years of cumulative power failure hours after the date of
shipment
Special battery, 100-time printing or 24 hours (optional)
Temperature: -5˚ to + 45˚C
: + 23˚ to + 113˚F
Humidity: 20 to 80%RH, no condensation
The unit operates normally at temperatures of 5˚C or below, but
the print density, reaction of the liquid crystal display, and the
number of prints at power failure are inferior to those at normal
temperature operation.
6.3" (w) x 8.07" (h) x 5.04" (d)
160 (w) x 205 (h )x 128 (d) mm
Approx. 3.5lbs. (1.6kg)
120VAC 50/60Hz 0.3A
100 employee capacity
Optional battery (not included) for 100% printer operation during power failures is
available. Order part no. VIS6020
Place the time recorder at the position close to the wall outlet so that it is easily accessible
to disconnect.
Lithium battery contains perchlorate material - special handling may apply.
Please go to the web site http://www.dtsc.ca.gov/hazardouswaste/perchlorate for
information about proper methods of disposal.
Ni-MH Battery rated 8.4V, 600mAh. Caution: Replace only with the same type of battery
specified by the manufacturer.