4.2.Description of installation programs.
P-0 electric catch unlock
catch
unlock
0
A procedure used during installation and adjustment of the electric catch. Each
touch on 0 results in operation of the electric catch during a time equal to a preset
parameter value (default value - 5 seconds).
P-1 Main installation procedure.
This procedure is used during installation of the system. It allows the control panel
to be called from an uniphone installed in a flat by depression of the door opening
pushbutton. The door phone seek an uniphone with removed handset calling it
initially without the ring signal. Talk and the catch unlock is enabled. After placing
the handset on the cradle the door phone is connected to the same uniphone again,
to check the call signal. A number of the flat is displayed. Confirmation signal of
the coded lock is also produced. The uniphones are sought within range of numbers
specified by the user. For example, this procedure can be used for one floor only,
specifying the lowest and the highest flat number for a given floor. This reduces a
time required to find the calling uniphone and at the same time provides protection
against interference produced by uniphones beyond the specified range.
1
pressing
a button
in uniphone
Searching
found
uniphone
lack of uniphones
with removed
handset
or
The seek upper and lower limits can be set in the P-1 level of the procedure.
C
2
+
C
2
+
lub
1
2
3
C
old value
new value
To be acceptable for the system, the upper limit must be equal to or higher than
the lower limit. Remember that true number of a flat (not its physical number in the
system) should be entered. For this reason attention should be paid to a method
of numbering (storey or normal) and to the range
shift parameter as their incidental change will result in incorrect interpretation of
the entered numbers.
NOTE:
The limits are not permanently stored, i.e. information is lost when the power supply