Checking Parts

 

 
Please check if the following parts are included: 
 
1 x Laser projector 
1 x Power cable 
1 x User manual 

Safety instructions 

If the device has been exposed to great temperature changes, do not switch it on immediately. 
Condensation water may damage your device. Leave the device switched off until it has reached room 
temperature. 
The laser must only be used for shows. Any operation has to be attended and supervised by a skilled 
and well-trained operator.   
Never leave this device running unattended and keep it away from children and unauthorized persons. 
Keep away from heaters and other heat sources. In order to safeguard sufficient ventilation, leave 50 
cm of free space around the device. 
Never direct the laser beam to people or animals. 
CAUTION LASER DIODE: If you open the device for cleaning, always disconnect from mains! 

HEALTH HAZARD! Never look directly into the light source, as sensitive persons may 
suffer an epileptic shock!

 

These lasers are considered a definite eye hazard, particularly at the higher power levels, which WILL 
cause eye damage. So these laser series models supplied with a key switch to prevent unauthorized 
use, warning labels and aperture labels affixed to the laser. 

Installation safety 

Prior to installation and operation of the laser, the paths of the beams and effects should be 
considered, particularly with respect to how they will reach the audience. If direct audience scanning 
is desired, then the laser energy in the effects needs to be considered to decide if the effects are safe 
for direct viewing. Always ensure, that the maximum permissible exposure (MPE) is not exceeded in 
the area accesible to the public. So install the laser in such a way, that minimum distances and 
heights ensure the MPE is never exceeded in the public area. 
When setting up the laser, make sure the laser is affixed firmly, to avoid vibrations. 

Warning labels on the device 

Laser radiation 

Read manual  

 

before use 

Avoid exposure 

Operation by qualified 

To the beam 

personal only 

Laser class 4 

Never direct laser  

 

Beam at people 

Caution of radiation 

Never look directly  

If cover is removed 

into beam  

 
Indoor use only 
At front opening:  

Avoid exposure – laser radiation is emmited. 

OPERATING THE LASER 

Don’t remove the warranty/serial number label - removal voids warranty 
The operator has to make sure that laser radiation – for laser class 4 also reflected laser radiation – 
higher than the maximum permissible level is avoided by technical or organisational measures. 
(Especially with respect to the MPE, see above.) 
Make sure to use the correct voltage. Use a power socket with earth/ground. 

Don’t use dimmer, 

RC,

 or other 

electronically switched

 sockets. Whenever possible, don’t use the laser together with 

large appliances, especially fog machines, on the same mains! 
If the device is used in a flying installation, the mounting brackets and an appropriate safety-rope 
must be afixed. 
In some countries, the operator must notify the accidence insurance and the authority for industrial 
safety, before operating a laser. For more information, contact the relevant authorities. 
Please consider that unauthorized modifications on the device are strictly forbidden due to safety 
reasons! 

Summary of Contents for PL-1200G MH

Page 1: ...00G MH PL 2000G MH PL 1500RGB MH PL 2800RGB MH Manual Bedienungsanleitung Please read this manual carefully before use Bitte lesen Sie diese Bedienungsanleitung bevor Sie das Gerät in Betrieb nehmen Seite 12 ...

Page 2: ...ergy in the effects needs to be considered to decide if the effects are safe for direct viewing Always ensure that the maximum permissible exposure MPE is not exceeded in the area accesible to the public So install the laser in such a way that minimum distances and heights ensure the MPE is never exceeded in the public area When setting up the laser make sure the laser is affixed firmly to avoid v...

Page 3: ...cially not with optical instruments Do not touch the device with wet hands When the laser diode becomes dim or broken please contact your dealer When returning laser to dealer manufacturer always use original packaging Maintenance should be performed every 15 day period See cleaning further down To ensure maximum lifetime of the laser Don t overheat the laser Always ensure good ventilation Don t h...

Page 4: ...MANUAL Laserworld Purelight Moving Head Rev September 10 Page Seite 4 of 14 ...

Page 5: ...MANUAL Laserworld Purelight Moving Head Rev September 10 Page Seite 5 of 14 ...

Page 6: ...MANUAL Laserworld Purelight Moving Head Rev September 10 Page Seite 6 of 14 ...

Page 7: ...MANUAL Laserworld Purelight Moving Head Rev September 10 Page Seite 7 of 14 ...

Page 8: ...W Working mode ILDA DMX512 automatic mode stand alone programmes Laser source aircooled DPSS laser green diode laser red blue in RGB models Optical power at the laser max green red Blue beam ca PL 1200 G MH 1200 800mW 532nm 3mm 1 5mrad PL 2000 G MH 2000 1200mW 532nm 3mm 1 5mrad PL 1500 RGB MH 1500 500mW 532nm 400mW 640nm 250mW 445nm 3mm 1mrad PL 2800 RGB MH 2800 1000mW 532nm 550mW 640nm 650mW 445n...

Page 9: ...n grossen elektrischen Verbraucher insbesondere Nebelmaschinen zusammen auf derselben Leitung Sorgen Sie immer für eine ausreichende Belüftung Insbesondere dürfen die Belüftungsöffnungen nicht verdeckt sein Netzstecker Kaltgerätebuchse zugänglich halten Stellen Sie sicher dass das Gerät nicht zu heiss wird Überprüfen Sie nach einer Installation an einem neuen Platz nach ca 15 30 Minuten ob die Abl...

Page 10: ...ation Gehäuse öffnen und nachprüfen ob sich Kondensat bildet Gegebenenfalls Position von Laser Nebelmaschine ändern Gerät ausschalten wenn es nicht benutzt wird Auch wenn die Diode nicht leuchtet sie ist an solange das Gerät an ist Warnhinweise am Gerät Laser Strahlung Vor Benutzung Anleitung durchlesen Nicht dem Strahl Betrieb nur durch aussetzen qualifiziertes Personal Laserklasse 4 Laserstrahl ...

Page 11: ... Musik oder DMX512 Um festzustellen ob ein ILDA Interface mit dem Gerät verbunden ist werden die Pins 4 und 17 des ILDA Anschlusses ausgewertet Sind diese verbunden dann wird das Gerät vom ILDA Interface und damit vom Computer aus gesteuert Wichtig Die Scanner sind für eine Scangeschwindigkeit von ca 22000 PPS bei ca 30 Bildwinkel eingestellt Falls Sie die Geschwindigkeit erhöhen unbedingt die Bil...

Page 12: ...everse Einstellungen Ja normale Richtung Nein umgekehrte Richtung Tilt reverse Tilt reverse Einstellungen Ja normale Richtung Nein umgekehrte Richtung Displaybeleuchtung Rücklicht ausschalten An Licht an Aus Licht aus Reset Lichteinstellung zurücksetzen Lichteinstellungen auf Ursprung zurück Betriebsweise Bedienpult 1 Wenn Sie auf MODE drücken dann wählen Sie den Arbeitsmodus aus 2 Wenn Sie auf UP...

Page 13: ...00 Grad Reinigung Reinigen Sie das Gerät regelmäßig um seine lange Lebensdauer zu erhalten Trennen Sie dazu das Gerät unbedingt zuvor vom Netz Schauen Sie niemals direkt in den Laserstrahl Zum Abnehmen des Deckels am Kopf des Gerätes entfernen Sie bitte die Schrauben Der Deckel lässt sich nun abnehmen Entfernen Sie eventuelle Staubansammlungen insbesondere im Bereich der Lüfter und Laser Sollten s...

Page 14: ...okalen Sicherheitsbestimmungen und die Warnhinweise in der Betriebsanleitung beachten Schäden die durch unsachgemäße Handhabung entstehen unterliegen nicht dem Einflussbereich der Herstellers und Händlers Somit wird keine Haftung bzw Gewährleistung übernommen Sollten Änderungen an dieser Bedienungsanleitung vorgenommen werden können wir Sie darüber nicht in Kenntnis setzen Bitte kontaktieren Sie f...

Reviews: