background image

Manual / Bedienungsanleitung: EL-200 LED 

Version / Stand: Jun-13 

Page / Seite 4 of / von 10 

Operation requirements 

The operator has to make sure that laser radiation – also reflected laser radiation – higher than the 

maximum permissible level is avoided by technical or organisational measures 

Make sure to use the correct voltage. Always use a grounded mains connection. Don’t use a remote 

controlled or other electronically switched main connection. Don’t use together with large appliances 

(especially fog machines/hazers) on the same mains. 

If the device is used in a flying installation, the mounting brackets and an appropriate safety-rope 

must be fixed. 

In some countries, the operator must notify the accidence insurance and the authority for industrial 

safety before operating a laser. For more information, contact the relevant authorities. 

Please consider that unauthorized modifications on the device are strictly forbidden due to safety 

reasons! 

If this device will be operated in any way differently than described in this manual, the product may 

suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to 

dangers like short-circuit, burns, electric shock, etc. 

Keep surrounding dry and clean. T

his unit should be keep dry, do not use in the rain or damp and 

dusty environment, don’t place liquid filled receptacles on the device. Projector should be put in a 

water-proof housing when operated outside.  

Regularly open the device (see “cleaning” further down) to check for dust inside, or if fog fluid 

condenses in the housing (if so rearrange hazer and/or laser position). 

Operating temperature is 10~35

°C

. In a new installation, check after some 15-30 minutes whether 

the outlet air gets too warm. Regularly check the inside for dust deposits, especially around the fans. 

Let laser cool off 10 minutes after 2 hours of operation, to ensure maximum lifetime for the diode. 

Be careful not to direct stage lights toward the laser (especially moving heads), this can cause 

overheating. 

Distance between laser aperture and projection screen should be not less than 1 meter. 
Do not turn device on and immediately off again frequently. 

Do not look into the laser beam directly, especially not with optical instruments. 

Do not touch the device with wet hands. 

When the laser diode becomes dim or broken, please contact your dealer timely. 

When returning laser to dealer/manufacturer always use original packaging.

 

Maintenance should be performed every 15-day period. See “cleaning” further down.

 

Operation 

Caution – use of controls or adjustments or performance of procedures other 
than those specified herein may result in hazardous radiation exposure. 

Connect the power cable to the mains. The red LED on the front panel should turn on and the laser 

beam will exit through the front opening – be careful. Now the device is in automatic mode.  

Sound-/automatic mode 

In automatic mode the patterns will be displayed automatically in a round robin fashion. Operating 

switch 1 will set the device to sound mode. In sound mode the patterns are changed and animated 

to the beat of the music. You can control the music-sensitivity of the microphone with the min-max 

knob at the back panel, the Mic LED flashes when the audio is triggered. 

DMX control 

Setting Switch 10 to „off“ puts the device into DMX mode. Connect a DMX controller to operate the 

laser. The red LED on the back panel will flash as long as a DMX signal is detected. 
To set the DMX address of the lase use switches 1 to 9, each switch represent a number 

Switch 

number 

switch 

number 

32 

64 

Summary of Contents for EL 200 LED

Page 1: ...structions 3 Operation requirements 4 Operation 4 Sound automatic mode 4 DMX control 4 Maintenance cleaning 5 Troubleshooting 6 Technical specifications 6 Please note 6 Lieferumfang 7 Hinweise zur Inb...

Page 2: ...rantielabels erlischt sofort jeder Anspruch auf Gew hrleistung Wenn das Ger t grossen Temperaturschwankungen ausgesetzt war nicht sofort anschalten Gefahr der Kondenswasserbildung Benutzen Sie immer e...

Page 3: ...AZARD Never look directly into the light source as sensitive persons may suffer an epileptic shock These lasers are considered a definite eye hazard particularly at the higher power levels which WILL...

Page 4: ...tes whether the outlet air gets too warm Regularly check the inside for dust deposits especially around the fans Let laser cool off 10 minutes after 2 hours of operation to ensure maximum lifetime for...

Page 5: ...en 120 255 Flashing red green with increasing speed 6 0 24 Normal operation 25 49 Laser on LED flashes 50 74 Laser LED flash alternating 75 124 Laser LED flash synchronous 125 174 Both on 175 199 LED...

Page 6: ...ode Lasersources aircooled DPSS laser green diode laser red Optical power at the laser max 200mW 40mW 532nm green 110mW 655nm red LED 5W RGB Beam ca 3mm 1mrad Laser class 3b Scanning system gratings W...

Page 7: ...cht verdeckt sein 9 Netzstecker Kaltger tebuchse zug nglich halten Warnhinweise 1 Betreiben Sie das Ger t nur gem ss dieser Betriebsanleitung 2 Die L ftungs ffnungen m ssen beim Betrieb des Geh uses f...

Page 8: ...werden Hierbei werden die Muster soundgesteuert gewechselt Um die Empfindlichkeit der Musiksteuerung einzustellen benutzen sie den Einstellknopf an der R ckseite des Lasers Die Mic LED blinkt wenn die...

Page 9: ...ahl Zum Abnehmen des Deckels entfernen Sie bitte die oberen beiden Schrauben an einem Seitenteil oben vorne hinten Biegen Sie das Seitenteil etwas nach aussen Der Deckel l sst sich nun anheben seitlic...

Page 10: ...wandfrei Der Benutzer des Ger ts muss die lokalen Sicherheitsbestimmungen und die Warnhinweise in der Betriebsanleitung beachten Sch den die durch unsachgem sse Handhabung entstehen unterliegen nicht...

Reviews: