background image

 User manual: CS-500RGBV 

Rev: 08/2009 

page2 of 6 

Checking parts

 

Please check if all listed parts are included, and are not damaged. Included: 
1 x CS-500RGBV laser 
1 x Power cable 
1 x 9-pin plug (dongle) 
2 x key 
1 x manual 

SAFETY INSTRUCTIONS  

If the device has been exposed to great temperature changes, do not switch it on 
immediately. Condensation water may damage your device. Leave the device 
switched off until it has reached room temperature. 
The laser must only be used for shows. Any operation has to be attended and 
supervised by a skilled and well-trained operator.   
Never leave this device running unattended and keep it away from children and 
unauthorized persons. 
Keep away from heaters and other heat sources. In order to safeguard sufficient 
ventilation, leave 50 cm of free space around the device. 
Never direct the laser beam to people or animals. 
CAUTION LASER DIODE: If you open the device for cleaning, always disconnect from 
mains! 

-

HEALTH HAZARD! Never look directly into the light source, as 

sensitive persons may suffer an epileptic shock!

 

These lasers are considered a definite eye hazard, 
particularly at the higher power levels, which WILL cause 
eye damage. So these laser series models supplied with a 
key switch to prevent unauthorized use, warning labels 
and aperture labels affixed to the laser. 

Installation safety

 

Prior to installation and operation of the laser, the paths of the 
beams and effects should be considered, particularly with 
respect to how they will reach the audience. If direct audience scanning is desired, then the 
laser energy in the effects needs to be considered to decide if the effects are safe for direct 
viewing. Always ensure, that the maximum permissible exposure (MPE) is not exceeded in 
the area accesible to the public. So install the laser in such a way, that minimum distances 
and heights ensure the MPE is never exceeded in the public area. 

OPERATING THE LASER 

The operator has to make sure that laser radiation – also reflected laser radiation – higher 
than the maximum permissible level is avoided by technical or organisational measures. 
(Especially with respect to the MPE, see above.) 
Make sure to use the correct voltage 
If the device is used in a flying installation, the mounting brackets and an appropriate safety-
rope must be fixed. 
In some countries, the operator must notify the accidence insurance and the authority for 
industrial safety, before operating a laser. For more information, contact the relevant 
authorities. 
Please consider that unauthorized modifications on the device are strictly forbidden due to 
safety reasons! 
If this device will be operated in any way differently than described in this manual, the 
product may suffer damages and the guarantee becomes void. Furthermore, any other 
operation may lead to dangers like short-circuit, burns, electric shock, etc. 

Reviews: