background image

Glaser Jailer Active Window Instruction Manual 

 

CEB00XXX-53-000 

 

Issue 7          19 January 2021 

 
 

 
 

LASERMET 

 

GLASER JAILER 

 

INSTRUCTION MANUAL 

 
 
 
 

 

 

 
 

 
 

ACTIVE WINDOW 

LASER PROTECTION SYSTEM 

 

 

 
 
 
 
 
 

 

Summary of Contents for GLASER JAILER

Page 1: ...Glaser Jailer Active Window Instruction Manual CEB00XXX 53 000 Issue 7 19 January 2021 LASERMET GLASER JAILER INSTRUCTION MANUAL ACTIVE WINDOW LASER PROTECTION SYSTEM ...

Page 2: ...1 LASERMET GLASER JAILER Instruction Manual Contents 1 Declaration of Conformity 3 2 Safety Warnings 5 3 Concept 6 4 Wiring 7 5 Operation 7 5 1 Laser Detection 8 6 Specifications 8 6 1 Filter Window Specification 9 6 2 Dimensions 10 6 3 Environmental Conditions 11 7 Warranty 11 8 Contact Details 12 ...

Page 3: ...nd Controlgear EN 61010 1 2010 A1 2016 Safety Requirements for Electrical Equipment The Glaser Jailer Active Guarding Window System has a response time of 50ms and meets Performance Level e PLe under EN ISO 13849 1 The Active Guard Protection Times in accordance with EN IEC 60825 4 are shown below The user must ensure that the Laser Termination Time is less than the Active Guard Protection Time to...

Page 4: ...omplies with the basic requirements for health and safety as provided by the following directives and standards Standards EN 207 2009 AC 2011 Essential Requirements according to Annex II of the PPE Directive 89 686 EEC Product Type Laser Protection Filter Window screen for laser working places Material and Mechanical Properties PMMA Increased Robustness S Wavelength Ratings EN 207 2009 AC 2011 180...

Page 5: ...ay be made to tamper with the parts open them or use them outside of the parameters contained herein The units are only designed to be fixed to surfaces using their inbuilt fixing holes They must not come into contact with each other or any other moving part when in use The parts should never be subject to impact or mechanical strain Safety switches should never be defeated or bypassed It is imper...

Page 6: ...nterlock connector on the laser to disable the laser beam if there is an inadvertent laser strike on the window Because of the inherently fail safe detection technique used any failure of the sensor will also disable the laser There are no maximum or minimum beam diameter requirements and no maximum or minimum laser power limits very low power densities may not cause the system to trip but they wi...

Page 7: ...details are given at the end of this manual 4 Wiring The Active Window has four connections to the ICS 6 via the plug in Active Window Interface Card These connect to the start and end of two conductive tracks on the window s sensor panel The terminal blocks on the Active Window Interface Card are marked A and B to indicate the separate circuits The two circuits are interchangeable The Active Wind...

Page 8: ...ay be possible though unlikely to arm the laser after a laser strike to the window it is strongly recommended that a damaged window is repaired or replaced prior to any use of the laser 6 Specifications IEC 60825 4 Protective Exposure Limit 8900 x 540mm Active Window For 450 1200 nm wavelength Area PEL Active Guard Protection Time 4 mm2 5 GW m2 0 5 s 2000 mm2 10 MW m2 5 s Note that the Active Guar...

Page 9: ...o engineering drawings ready for assembly in sizes up to a maximum of 600 x 800mm Laser Filter viewing windows enable processes to be viewed within a laser enclosure Specifications Part No FW LM 1064 7 Wavelength 920 1175nm Material Acrylic Maximum Size 800 x 600 Thickness 3 5mm Wavelength 1064 OD 7 VLT 40 Wavelength Ratings to relevant standards EN 207 2009 AC 2011 180 315 D LB8 IR LB4 315 380 D ...

Page 10: ...0 D AB2 I AB3 5000 11000 6 2 Dimensions The active protection is effective only on the window area and not on the mounting flange The window is mounted with the flange on the outside of the laser enclosure Dimensions are approximate Values given as typical are average values measured across a number of samples and are not guaranteed Lasermet reserve the right to alter any specification without pri...

Page 11: ... materials and manufacture from the date of installation or delivery Installations completed by Lasermet are covered against defects in workmanship for 12 months Damage or defects caused by other factors are not covered For example industrial contamination incorrect cleaning storm damage Consequential loss is not covered under warranty Compensation for indirect or direct loss or damage is expressl...

Page 12: ...ected to provide a complete system We also supply equipment and consultancy covering all aspects of laser safety Full support design and installation is available from Lasermet please contact us for any queries For sales and technical support Lasermet Ltd Lasermet House 137 Hankinson Road Bournemouth BH9 1HR United Kingdom Tel 44 0 1202 770740 Fax 44 0 1202 770730 Email sales lasermet com Website ...

Reviews: