LaserBit Giga Series 4.3 page
48
10.6 48 VDC Power supply connections
In fact the 48VDC power supply is optional, the connection is almost the same. In
the case of the 48VDC power supply it is important to pay attention to the polarities.
The wrong polarity of
the cables can damage
the power supply.
0
-48VDC
In this type of ODIU you can find fuses only on the primarily side of the
transformer.
Type GigaPICO
GigaPINTO GigaPRONTO
fuse T6,3A(250V) T6,3A(250V) T6,3A(250V)
In this case you have the 3 poles connector for the head power supply for every type
of heads. So the connecting order is as follows, which must be followed:
Color coding GigaPico:
Green positive
Twisted:
orange-White,
Green-White
GND
Orange negative
Color coding GigaPinto, GigaPronto:
Red positive
Green-Yellow GND
Black negative