A
PPENDIX
A: S
ERIAL
I
NTERFACE
S
PECIFICATIONS
Electronic Copy of LTI’s UltraLyte User’s Manual – 7
th
Edition June 1998
70
Speed/Range Data Message Format
Speed and range data downloaded in 20/20
mode has the following general format:
speed
,
range
<CR><LF>
where:
speed
is the speed measurement. Legal values are
000 to 199, preceded by a minus sign if the
target was departing when the measurement
was taken.
range
is the range measurement. Legal values are
0000.0 to 9999.9, unsigned.
<CR><LF>
is a carriage return/line feed.
Note that this format has no units indicators. The
values are in the units in effect when the
measurement was taken.
If a measurement error occurs, the speed and
range values are replaced by an error code in
the form
E
xx
, where
xx
is the error code. See
“Error Conditions” for the error code values.
Example Speed/Range Messages
English units:
50,700.0
Metric Units:
80,213.4