Align the Tilt Sensor
The tilt sensor is aligned during assembly. In the rare event that your TruPulse 360
R suffers a severe
drop shock, refer to the instructions below to re-align the tilt sensor.
1.
From the Measurement Mode, press
for 4 seconds to access the System Setup Mode. “UnitS”
will appear in the Main Display.
2.
Press
to display the “inc” option as shown in Figure #13 below.
3.
Press
to select the “inC” option. The message “no" "CAL” appears in the Main Display and
the display should look similar to Figure #13.
Press
or
to display the previous or next "CAL" option.
If "no" "CAL" is displayed, press
to exit the "inC" option and return to the Measurement Mode.
If "YES" "CAL" is displayed, press
begin the Tilt Calibration Routine.
The message "C1_Fd" appears in the Main Display.
Figure #13