![Laser Technology TruPulse 200X User Manual Download Page 53](http://html2.mh-extra.com/html/laser-technology/trupulse-200x/trupulse-200x_user-manual_3755369053.webp)
Section 6 – Serial Interface
Page 49
Height (HT) Download Messages
$PLTIT,HT
,HTvalue,units,*csum
<CR><LF>
where:
$PLTIT,
is the Criterion message identifier.
HT,
Height
message
type.
HTvalue,
Calculated Height. Two decimal places.
units,
F=feet
Y=yards
M=meters
*csum
An asterisk followed by a hexadecimal checksum.
The checksum is calculated by XORing all the
characters between the dollar sign and the asterisk.
<CR>
Carriage
return.
<LF>
Optional linefeed.
Example:
$PLTIT,HT,22.10,F*0C