OPERATION
This lamp comes preconfigured with selected voltage and cord cap.
1.
Position light head in desired location using swivel hook.
2.
Attach power cord from light to compatible receptacle with
VOLTAGE
SPECIFIED ON PRODUCT LABEL
.
WARNING:
Check product label for correct voltage! Failure to comply could
result in damage to the fixture which may not be covered by warranty. The bulb itself
runs on voltage specified upon purchase.
The LED lamp in this hand lamp is “instant-on” and will illuminate once power is supplied.
LAMP REPLACEMENT
1.
Loosen set screw.
⑧
2.
Unscrew Guard/Globe assembly
⑨
from handle assembly.
3.
Replace with matching lamp.
4.
Inspect o-ring seal
⑪
. If worn or damaged, it must be replaced to
insure watertight seal.
5.
Screw globe assembly completely onto lamp base.
6.
Tighten set screw securely to 6 in-lbs.
Note:
Over tightening can deform threads.
MAINTENANCE
Caution:
To avoid personal injury, disconnect power to the light
and allow the unit to cool down before performing maintenance.
Warning:
No user serviceable parts inside of fixture. Risk of
electric shock. Removal of the lens will void the warranty.
1.
Perform visual, mechanical and electrical inspections on
a regular basis. We recommend routine
checks to be
made on a yearly basis. Frequency of use and
environment should determine this. It is
recommended
to follow an Electrical Preventive Maintenance Program
as described in NFPA 70B:
Recommended practice for
Electrical Equipment.
2.
The lens should be cleaned periodically as needed to
ensure continued photometric performance.
Clean the
lens with a damp, non-abrasive, lint-free cloth. If not
sufficient, use mild soap or a liquid
cleaner.
3.
Inspect the cooling fins on the luminaire to ensure that
they are free of any obstructions or
contamination (i.e.
excessive dust build-up). Clean with a non-abrasive
cloth if needed.
4.
Do not operate if the lens is cracked or damaged. All
fasteners should be properly seated.