WARNING:
USER SHOULD BE TRAINED IN THE PROPER USE AND MAINTENANCE OF THIS DEVICE. WHEN EXTENSION
CORD IS CONNECTED TO A POWER SOURCE IN HAZARDOUS AREA, PLUG AND MATCHING RECEPTACLE
MUST BE SUITABLE FOR HAZARDOUS LOCATION INVOLVED. IMPROPER USE OF THIS DEVICE, ASSOCIATED
PLUG, RECEPTACLE, AND CORD CAN LEAD TO SERIOUS INJURIES OR DEATH TO PERSONNEL.
PERIODIC INSPECTION OF THE RECEPTACLE AND CORD IS NECESSARY.
THE CORD MUST BE ROUTINELY CHECKED FOR CUTS, BREAKS, OR ANY SEVERE ABRASIONS, AND IF ANY
ARE FOUND, THE CORD MUST BE REPLACED BEFORE RESUMING USE OF THE UNIT.
ELECTRICAL POWER SUPPLY MUST BE “OFF” BEFORE AND DURING INSTALLATION AND MAINTENANCE.
INSTALLATION AND MAINTENANCE PROCEDURE MUST BE PERFORMED BY A TRAINED AND COMPETENT
ELECTRICIAN.
IF ANY PARTS OF THE RECEPTACLE OR PLUG APPEAR TO BE MISSING, BROKEN, OR SHOW SIGNS OR
DAMAGE, DISCONTINUE USE IMMEDIATELY. REPLACE WITH THE PROPER REPLACEMENT PART(S) BEFORE
CONTINUING SERVICE.
The Larson Electronics EHL-LED-7W-25-1523 Explosion Proof LED Drop Light / Trouble Light is UL Listed Class 1
Division 1 & 2 Groups C and D - and is ideal for general work activities in hazardous locations requiring explosion proof
protection.
WIRING
Standard pigtail(flying leads) wiring
We strongly encourage a licensed electrician install this product
, in all locations especially in outdoor areas
where weatherproofing may be required. Universal voltage driver permits operation at 1
2
0V - 277V AC,
12VAC,
24VAC.
Warning:
Check product label for correct input voltage!
Attach supply line wires to the appropriate light fixture wires as shown
in the diagram
Secure each pair of wires according to the diagram. Utilize a junction box or
similar device and take precautionary steps for weatherproofing all
connections if installed in a location where water may come in contact with the
unit. Ensure the unit is properly grounded and that wiring is done according to
all local and national electrical/building codes.
Exp Cord Cap
Position device near work area for operation. Run cable to nearby power
source. Insert and twist-lock explosion-proof plug into a compatible receptacle within
the hazardous environment. See
plug operation
below.
PLUG OPERATION
Electrical connection between plug and compatible receptacle is accomplished
after plug fully inserts into receptacle and rotated clockwise.
1.
Lift receptacle door and locate polarization on mating plug pin and
receptacle face. Insert plug straight all the way into receptacle until it
cannot go further.
2.
Rotate plug clockwise limit (37º), this closes internal contacts and
completes circuit. This also mechanically locks plug into receptacle so it
cannot be pulled out.
3.
To remove plug, push plug inward and turn to counterclockwise, pull plug
straight out.