CHECK ON POWER SUPPLY
Make sure that the system is properly grounded.
Use an electrical plug which guarantees the proper
grounding of the system.
DO NOT use thread pastes upon the connections.
It is recommended to use the tubes which have been
supplied along with the machine.
NEVER use a damaged or repaired flexible tube.
The machine requires a 220V alternating current
power supply.
LARIUS MINI-MIX
equipment is fitted with an additional external
earth cable that is connected to the stem on the pump unit be means
of a specific clamp (
F6
), in order to protect the operator against any
risk of static or electric shock.
Should anyone use an extension cable between
the tooling and the socket, it must have the same
characteristics as the cable supplied (minimum
diameter of the wire 4 mm2) with a maximum length
of 50 mt. Higher lengths and lower diameters
can provoke excessive voltage falls and also an
anomalous working of the equipment.
• The fourth tube
(
F4
) is to be connected to the mixing tube’s
outlet (
F5
) and connected to the spray-gun.
Make sure that the connections are tightly sealed. It is recommended
to use two wrenches to tighten them.
F6
F4
F5