background image

   44428235 

ASSEMBLY INSTRUCTION

 

 

Valid from: 

17.07.2019

 

EPIC

®

 SOLAR 4 PLUS 

 

Document: L44428235EN 
Version: 02 

Page 8 of 9 

We reserve all rights according to DIN ISO 16016. 

Mounting 

Insert the crimped contact into the opened cable gland until the contact clicks into place. 
Lightly pull the cable to make sure that the contact is properly engaged.  
Turn cap nut “hand-tight” (4,5 Nm) – finished. Spanner size 19.  
 

 

 

 

 
(EPIC

®

 SOLAR 4PLUS F) 

 
 

Connecting and Disconnecting 

Before plugging in, check the plug-in area for any dirt and, if necessary, clean it. Especially the 
O-ring on the female connector must be absolutely clean. Remove moisture. Connect EPIC

®

 

SOLAR 4 PLUS, male and female until the snap-in hooks are completely engaged on both sides. 
 

 

 
 
To disconnect, press the latching hooks on both sides with the standard pliers (article 
3115160) and pull them apart carefully but firmly.  

 

 
 

 

Summary of Contents for 44428217

Page 1: ...to DIN ISO 16016 EPIC SOLAR 4 PLUS ASSEMBLY INSTRUCTION Contents Scope of delivery 2 Contacts 2 Technical Specifications 3 Safety Instructions 4 Necessary Tools 5 Mounting of EPIC SOLAR 4 PLUS 6 Analy...

Page 2: ...PLUS is delivered pre assembled the necessary contacts are included separately EPIC SOLAR 4 Plus X Y Item number Designation 44428235 EPIC SOLAR 4 PLUS M 4 0 mm or 6 0 mm 44428236 EPIC SOLAR 4 PLUS F...

Page 3: ...014 Rated Voltage 1 500 V DC Rated Current 30 A 4 0mm 30 A 6 0mm 30 A 10 mm Rated impulse withstand voltage 16 kV Rated temperature 40 C 85 C Upper Limit of Temperature 105 C Protection degree IP68 10...

Page 4: ...DC 1 5 kV max Voltage DC 1 8 kV Conductor Earth System without Earth Connection Mated connectors are IP68 protected 1m 10 h A permanent use under water e g water on the roof of a flat roof is not pos...

Page 5: ...able LAPP Universal Strip Solar Item number 21920120 EPIC SOLAR Mounting Tool is not necessary Two 19 mm open end wrenches are enough Crimping Tool Note To comply the tested quality it s necessary to...

Page 6: ...male Connector field mountable including Contacts 44428236 EPIC SOLAR 4PLUS F 4 mm 6 mm 4 6 5 2 7 1 8 30 44428238 EPIC SOLAR 4PLUS F 10 mm 10 5 2 7 1 12 30 EPIC SOLAR 4PLUS Male Connector field mounta...

Page 7: ...pletely into the crimp area of the contact The cable is pushed forward until the insulation strikes the crimp receptacle of the contact In this way the supermatent is insured at least 2 mm Completely...

Page 8: ...erly engaged Turn cap nut hand tight 4 5 Nm finished Spanner size 19 EPIC SOLAR 4PLUS F Connecting and Disconnecting Before plugging in check the plug in area for any dirt and if necessary clean it Es...

Page 9: ...The cables must be laid firmly in the photovoltaic system securely fastened and the minimum bending radius shall not be undercut The cable shall be led out staight at least L 50 mm The bending radius...