Lapcon LAMP LDD-S Installation Instructions Download Page 1

1- 2mm   

2-

3

m

m

26

(S

c

re

w

 h

o

le

 

fo

s

tr

ik

e

)

D

Unit : mm

                 mark the screw hole shown on the template.

Closing power adjustment

Loosen adjustment screw, adjust strike plate position and re-tighten 

・This damper may not be able to slow down the door if it is closed with excessive force.

 ・This product is a SURFACE MOUNT TYPE door closer damper intended to be applied on the head frame.

 ・The damper function reduces door slamming sounds and the door begins to close slowly 

Installation

 the Closing power adjustment screw.

Attach the covers for the main unit and the 

Indicator

High

      just before the complete closing and closes completely.

Closing power adjustment screw

(Surface mounted)

Installation and usage notices

・The LDD may not pull the door completely closed when using and overly hard latch.

Installation instructions

Lapcon Door Damper 

・Sugatsune's waranty is for the product itself and does not extend to the installation as a whole.

 ・The strike plate is featured with vertical/horizontal adjustment functions.

Parts list

・Despite extensive in-house testing , we recommend that you test your installation for proper
   interaction between the hinge and the LDD damper. 

LDD-S

 ・Featured with the function of door-closing power adjustment.

*LDD-S body : 1pcs

*Body cover : 1pcs

   Read this manual thoroughly for proper and safe installation. Please retain this manual for future
   reference.

*Strike plate unit : 1 pcs

*Strike plate cover : 1 pcs

Body installation screw : 2pcs

    (nominal 4×16)

Instruction Manual (this manual) :1

Strike plate installation screw : 2pcs

 ・Quick and easy to install. Just mount it close to the vertical frame and door stop.  (*Depends on the frame width.)

Body

Left-hand opening type (LDD-S-L) is symmetrically opposed.

4.Attaching the covers

Vertical adjustment screw
Vertical adjustment range:+3,-2mm

Suggested hinge

  strike plate while keeping the door open.

This only changes the final closing power, not the 

Low

Highe          Lower

damping force of the LDD-S. 

screw.
Check roller position and adjust further if necessary.
When adjustment is completed, open and close the door several times 
in order to check proper function of the LDD-S.

Checking before the installation

*RIGHT HAND TYPE (LDD-S-R) SHOWN.  LEFT HAND TYPE (LDD-S-L) SYMETRICALLY OPPOSITE.

・Concealed hinge

Installation

・If C is between 20 mm and 25 mm:

Template for strike plate : 1pc

  

(nominal 3.5×30)

Strike

This drawing shows a right-hand opening type (LDD-S-R). 

 Product functions and features

   In case of failure, Sugatsune's liability is limited to the replacement of the products by a similar one.
・The company is conducting strict check on the products, however, if any defects are found on the
   product, contact retailer. 
・The warranty period is one year after the day of shipment. The company s responsibility shall be 
   limited to replacement of the product.

Install and fully adjust the door, hinges and frame before installing the LDD-S

2.Strike plate installation procedure

・This product is for indoor use only. Do not use in locations where it is in direct contact with water.

Applicable door specifications

・Door weight range: 15-40 kg (33.6-88 lbs.)

・This damper effectiveness maybe lessened when use in an environment subject to strong drafts.

・Maximum door width: 900 mm (36")  

              

3.Adjustments

・Butt hinge ( Dimension D must be 60mm or less )

・Standard temperature of use is 0 to 40 ℃.  

    Mounting position and installation screw holes depend on the top frame mounting width C

FIG 1-A

・If C is  25 mm or more:

FIG 1-B

OR

FIG 2

 Square hole

Left-hand opening

Right-hand opening

 

1.Main unit installation procedure

FIG 3

Adjust the template so that it is parallele with the top of the door and

                  in the square hole shown on the template.

Screw holes

FIG 4

           screws provided.

: Fix the strike plate with the installation 

           the strike plate. (See below.)

before opening and closing the door.

Proceed with the final adjustment 

FIG 4

FIG 5

           If necessary, carry out vertical and/or horizontal adjustments to 

           the guide groove on the strike plate as shown.

: Close the door carefully and make sure that the roller enters into

FIG 5

Check you door opening side

・If the hinges are on your right when pulling the door open, choose the "Right-hand" opening type.
・If the hinges are on your left when pulling the door open, choose the "Left-hand" opening type.

Size of door stopper and top frame (applicable size range)

A - Maximum height of door stopper: 15 mm
B - Distance from door to the back of the door stopper
     (= door s packing thickness): 23-33 mm

C - Minimum top frame mounting width: 20  mm

FIG 2-3

: ①

Deploy the arm and close the door slowly until the arm touches the door.

              

Insert the template between the arm and the door so that the arm roller fits

Horizontal adjustment screw
Horizontal adjustment range:±3mm

Closing power of the door can be adjusted by turning

Top frame

Door stop

Door

B

A

C

132

32

.5

50

152

(This drawing shows a right-hand opening type (LDD-S-R). Left-hand opening type (LDD-S-L) is symmetrically opposed.)

Center of butt hinge

Installation drawing

Door

Hinge side mounting frame

Body

Strike

17

.5

60

9

198

35

212

Door stop

: Line up the LDD-S body with the top door stop and hinge 
  side mounting frame. Fix the body with the provided body 
  installation screws.

Door stop

FIG 1-A

Hinge side mounting frame

Screw holes

FIG 1-B : Line up the LDD-S body with the top door stop and 25mm 

              away from the hinge side mounting frame. Fix the body with 
              the provided body installation screws.

C

Screw holes

Hinge side mounting frame

mm

25

C

Arm

R

+

Reviews: