LA-VST-LCD 

(V.1.1 2011)                                                                                                                                                                                                                 

LA-VST-LCD 

(V.1.1 2011)   

                   

 

CAUTION: NEVER connect a laser printer or scanner to the 
UPS unit. This may cause the damage of the unit.   

 

4 hours 

 

1. Package Contents 

You should have received the following items inside of package:   
- UPS Unit 

- Quick Guide 

- USB Cable   

- CD Software 

- Power cable (only in LA-VST-1500/2000-LCD) 

 

2. Product Overview 

Front view: 
 
 
 
 
 
 
 
 
 
 
 
 
Back View 
 

 

 

3. Installation and Initial Startup 

EN 

Line Interactive UPS LA-VST-1000/1500/2000-LCD 

NOTE: Before installation, please inspect the unit. Be sure that nothing inside the package is 
damaged.  
 
Placement & Storage Conditions 
Install the UPS in a protected area that is free of excessive dust and has adequate air flow. 
Please place the UPS away from other units at least 20 cm to avoid interference. Do NOT 
operate the UPS where the temperature and humidity is outside the specific limits. (Please 
check the specs for the limitations.) 
 

 

LCD Display:   

Display LCD

LCD Display

On-Off switch 

On-Off switch 

LCD Display 

 

 Input Voltage   
 Output Voltage   
 AC mode indicator   

Connect to Utility and Charging 
Plug in the AC input cord to the wall outlet. For the best results, 
suggest charging the battery at least 4 hours before initial use. 
The unit charges its battery while connecting to the utility. 

 Battery mode indicator 

 Load level indicator, flashing 

indicates overload 

 Battery capacity indicator, flashing 

indicates low battery 

 
Connect the Loads 
Plug in the loads to output receptacles on the rear panel of the 
UPS. Simply turn on the power switch of UPS unit, then devices connected to the UPS will be 
protected by UPS unit. 
 
 
 

 Output receptacles 

 

 AC Input 
 USB port 

Connect Modem/Phone for Surge Protection   
Connect a single modem/phone line into surge-protected “IN” outlet on the back panel of the 
UPS unit. Connect from “OUT” outlet to the computer with phone line cable.   

 

Modem/phone surge 

protection 

 
Connect Communication Cable 

Circuit breaker

 

To allow for unattended UPS shutdown/start-up and status monitoring, connect one end of 
the communication cable to the USB port and the other to the communication port of your PC. 
With the monitoring software installed, you can schedule UPS shutdown/start-up and 
monitor UPS status through PC. 
 
Turn On/Off the Unit 
Turn on the UPS unit by pressing the power switch. Turn off the UPS unit by pressing again 
the power switch.    