xSenso 2100 User Guide
46
12: Alarm Settings
An alarm setting is available in xSenso 2100. The address of the remote host to connect to can be
designated for when the alarm is turned on. Also emails can be sent when a specific profile
number is selected.
Table 12-1 Alarm Settings
To Configure Alarm Settings
Using Web Manager
To configure Alarm, go to the
Setup
tab/page, click
Alarm
in the menu.
Alarm Settings
Description
Select
(drop-down menu)
Select the connection for which to set the alarm. The settings in this page
will be set for the selected connection.
Terminal Block Power
Barrel Connector Power
Input 1
Input 2
Port
Enter the TCP or UDP
Port
required to enable the establishment of a
connection (when the alarm is on) on the remote host.
Protocol
Select the
Protocol
from the drop-down menu to be used on the
connection. If security is a concern, it is highly recommended that SSH
be used. When using SSH, both the SH Server Host Keys and SSH
Server Authorized Users must be configured.
SSH Username (SSH Only)
Specify the
SSH Username
(i.e., SSH Client User) to use for an outgoing
SSH connection.
AES Encrypt Key
(TCP AES or UDP AES Only)
Specify the text or hexadecimal Advanced Encryption Standard (AES)
key used for encrypting the outgoing data.
AES Decrypt Key
(TCP AES or UDP AES Only)
Specify the text or hexadecimal AES key used for decrypting the
incoming data.
Credentials (SSL Only)
Specify the name of the set of RSA and/or DSA certificates and keys to
be used for the SSL connection.
Reminder Interval
Specify how long to wait in minutes before trying to reconnect to the
remote host after a previous attempt fails or the connection closes. Blank
the display field to disable reminders. If more than one Connect host is
specified, connections are attempted without delay; so the single
Reminder Interval
applies to the delay between successive attempts to
them all.
Address
To establish a connection when the alarm is on, provide either a DNS or
IP address of the remote host.
Alarm Email
Select an alarm profile number which will send an email when the alarm
is turned on.
Normal Email
Select a normal profile number which will send an email when the alarm
is turned off.