C: Connections and Pinouts
XPress™ DR Industrial Device Server User Guide
85
Screw Terminal Serial Connectors
Table C-2 Serial Screw Terminal Pinouts
Pin
Direction
Name
Function
1
To XPress DR
RXD or RX-
RS-232: RXD (Received Data)
RS-422/485: RX- (Received Data -)
4
From XPress DR TXD or TX-
RS-232: TXD (Transmit Data)
RS-422/485: TX- (Transmit Data -)
2
To XPress DR
CTS or RX+
RS-232: CTS (Clear to Send)
RS-422/485: RX+ (Received Data +)
3
From XPress DR RTS or TX+
RS-232: RTS (Request to Send)
RS-422/485: TX+ (Transmit Data +)
8
Ground
GND
Ground
Note:
You can choose pin 5 or pin 8 as a ground (GND) pin.
Figure C-1 Serial Screw Terminal Pinouts
Note:
For RS-485 2-wire functionality, pins 1 & 4 and 2 & 3 of the screw terminals must be
connected together.
Note:
Termination resistors (R = 120 Ohm) are used to match impedance of a node to the
impedance of the transmission (TX) line. Termination resistors should be placed only at the
extreme ends of the data line, and no more than two terminations should be placed in any single
segment of a RS-485 network. The terminator resistors may not be needed for your application.
RJ-45 Ethernet Interface
XPress DR supports 10/100Mbit Ethernet through its RJ-45 (10BaseT/100BaseTX) connector.
Table C-3 Ethernet Interface Signals
Signal Name
DIR
PIN
Primary Function
ETX+
Out
1
Ethernet Transmit Data +
ETX-
Out
2
Ethernet Transmit Data -
ERX+
In
3
Ethernet Receive Data +
ERX-
In
6
Ethernet Receive Data -
RXD CTS RTS TXD
Rx- Rx+ Tx+ Tx-
GND
1
2
3
4
8
Data+ Data- GND
1 2
3
4
8
R
R = 120 Ohm, 1/8 W
RxD-
1 2
3 4
8
R
R = 120 Ohm, 1/8 W
RS-485 2-Wire
RS-422/485 4-Wire
R
RxD+
TxD-
TxD+
GND
RX- RX+ TX+ TX-
RX- RX+ TX+ TX- GND