7: Setup Mode: Server Configuration
XPress™ DR Industrial Device Server User Guide
45
7:
Setup Mode: Server Configuration
This chapter explains how to configure the server through Setup Mode. All current values are
displayed in parenthesis.
Server Configuration (Option 0)
These are the unit’s basic network parameters. The following parameters are displayed when you
select
Server configuration
.
IP Address : (172) .(019) .(205) .(058)
Set Gateway IP Address (Y) ?
Gateway IP addr (172) .(019) .(000) .(001)
Netmask: Number of Bits for Host Part (0=default) (0)
Set DNS Server IP addr (N) ?
Change Telnet/Web Manager password (N) ?
IP Address
If DHCP is not used to assign IP addresses, enter the IP address manually. The IP address must
be set to a unique value in the network. Enter each octet and press
Enter
between each section.
The current value displays in parentheses.
IP Address : (000) .(000) .(000) .(000) _
If DHCP is used, the third octet of the IP address sets the BootP/DHCP/AutoIP options. The
following table shows the bits you can manually configure to force the XPress DR device server
to disable AutoIP, DHCP, or BootP. To disable an option, set the appropriate bit.
Table 7-1 BootP/DHCP/AutoIP Options
Options Bit Value
AutoIP
0
1
DHCP
1
2
BootP
2
4
For example, if the third octet is 0.0.5.0, the AutoIP and BootP options are disabled; only DHCP is
enabled. (The value 5 results from adding the binary equivalents of 0 and 2.) This is the most
common setting when using DHCP.
Set Gateway IP Address
The gateway address, or router, allows communication to other LAN segments. The gateway
address should be the IP address of the router connected to the same LAN segment as the unit.
The gateway address must be within the local network. The default setting is
N
(No), meaning the
gateway address has not been set. To set the gateway address, type
Y
and enter the address.
Set Gateway IP Address (N) ? Y
Gateway IP addr (000) .(000) .(000) .(000)_