5: Configuration Using Web Manager
XPress™ DR Industrial Device Server User Guide
34
Serial Tunnel - Hostlist Configuration
The XPress device server scrolls through the host list until it connects to a device listed in the
host list table. After a successful connection, the unit stops trying to connect to any others. If this
connection fails, the unit continues to scroll through the table until the next successful connection.
The host list supports a minimum of 1 and a maximum of 12 entries. Each entry contains an IP
address and a port number.
Note:
The host list is disabled for Manual and Modem Mode. The unit does not accept a
data connection from a remote device when the hostlist option is enabled.
To configure the host list:
1. In the Navigation bar, click
Hostlist
.
Figure 5-5 Hostlist Settings
2. Update the following:
Retry Settings
Retry Counter
Enter the value for the number of times the XPress device server should
attempt to retry connecting to the host list. The default setting is
3
.
Retry Timeout
Enter the duration (in milliseconds) the XPress device server should
abandon attempting a connection to the host list. The default setting is
250
.
Host Information
Host Address
Enter or modify the host’s IP address.
Port
Enter the target port number.
3. When you are finished, click the
OK
button.
4. Click
Apply Settings
in the Navigation bar.