Configuration via Serial Mode or Telnet Port
WiBox™ User Guide
35
Option
7
6
5
4
3
2
1
0
Two
1
0
Send Characters
2-Byte Send Character
Sequence
1
Send Immediately After
Send chars
1
Packing Interval:
Packing Interval defines how long the unit should wait before
sending accumulated characters. This wait period is between successive network
segments containing data. For alternate packing, the default interval is 12 ms.
Trailing Characters:
In some applications, CRC, Checksum, or other trailing
characters follow the end-of-sequence character; this option helps to adapt frame
transmission to the frame boundary.
Send Characters:
If 2-Byte Send Character Sequence is enabled, the unit interprets the
sendchars as a 2-byte sequence; if this option is not enabled, the unit
interprets them independently.
If Send Immediately After Characters is not set, any characters already in the
serial buffer are included in the transmission after a "transmit" condition is
found. If this option is set, the unit sends immediately after recognizing the
transmit condition (sendchar or timeout).
Note:
A transmission might occur if status information needs to be
exchanged or an acknowledgment needs to be sent.
DisConnTime (Inactivity Timeout)
Use this parameter to set an inactivity timeout. The unit drops the connection if there
is no activity on the serial line before the set time expires. Enter time in the format
mm:ss
, where m is the number of minutes and s is the number of seconds.
DisConnTime (0: 0) ?:
To disable the inactivity timeout, enter
00:00
. Range is 0 (disabled) to 5999 seconds
(99 minutes, 59 seconds). The default is 0.
SendChar 1 and SendChar2
Enter up to two characters in hexadecimal representation.
SendChar 1 ( 0) ? _
SendChar 2 ( 0) ? _
If the unit receives a character on the serial line that matches one of these
characters, it sends the character immediately, along with any awaiting characters, to
the TCP connection. This action minimizes the response time for specific protocol
characters on the serial line (for example, ETX, EOT). Setting the first SendChar to
00
disables the recognition of the characters. Alternatively, the unit can interpret two
characters as a sequence (see
Pack Control
on page 34).
Summary of Contents for WiBox
Page 1: ...INSERT PICTURE HERE WiBox User Guide Part Number 900 351 Revision A June 2004 ...
Page 8: ...Contents 8 WiBox User Guide ...
Page 20: ...Installation 20 WiBox User Guide ...
Page 42: ...Configuration via Serial Mode or Telnet Port 42 WiBox User Guide ...
Page 56: ...Configuration Using Web Manager 56 WiBox User Guide ...
Page 57: ......