background image

Lantronix 

 

SMxTAT2SA Install Guide 

33716 Rev. L   

https://www.lantronix.com/

   

Certifications 

Electromagnetic Emissions (EMC) and Safety

 

EMC: CE, FCC Part 15 Class A 

Safety: IEC62368-1/EN62368-1, UL Listed   

EN 55032:2012, EN 55024:2010 

Directive 2014/30/EU, Directive 2015/863/EU 

Low-Voltage Directive 2014/35/EU 

2011/65/EU EN 50581:2012 

Normas Oficiales Mexicans (NOM)

 

Software Features   

Layer 2 Switching 

 

Spanning Tree 

Protocol (STP) 

  Standard Spanning Tree 802.1d   

  Rapid Spanning Tree (RSTP) 802.1w   

  Multiple Spanning Tree (MSTP) 802.1s 

Trunking 

  Link Aggregation Control Protocol (LACP) IEEE 802.3ad 

  Static aggregation 

VLAN 

Supports up to 4K VLANs simultaneously (out of 4096 VLAN IDs).   

Port-based VLAN; 802.1Q tag-based VLAN; Protocol based VLAN; IP subnet-based 

VLAN; Private VLAN Edge (PVE); MAC-based VLAN; Q-in-Q (double tag) VLAN;   

GARP VLAN Registration Protocol (GVRP) 

DHCP Relay   

  Relay of DHCP traffic to DHCP server in different VLAN 

  Works with DHCP Option 82 

IGMP v1/v2 

Snooping 

IGMP limits bandwidth-intensive multicast traffic to only the requesters. Supports 1024 

multicast groups.   

IGMP Querier 

IGMP querier is used to support a Layer 2 multicast domain of snooping switches in the 

absence of a multicast router 

IGMP Proxy 

IGMP snooping with proxy reporting or report suppression actively filters IGMP packets 

to reduce load on the multicast router 

MLD v1/v2 

Snooping 

Delivers IPv6 multicast packets only to the required receivers 

Multicast VLAN 

Registration   

MVR uses a dedicated manually configured VLAN, called the multicast VLAN, to forward 

multicast traffic over Layer 2 network in conjunction with IGMP snooping 

Security  

 

Secure Sockets 

Layer (SSL) 

SSL encrypts the http traffic, allowing advanced secure access to the browser-based 

management GUI in the switch 

IEEE 802.1X 

  IEEE802.1X: RADIUS authentication, authorization and accounting, MD5 hash, guest 

VLAN, single/multiple host mode and single/multiple sessions 

  Supports IGMP-RADIUS based 802.1X 

  Dynamic VLAN assignment 

Layer 2 Isolation 

Private VLAN Edge   

PVE (also known as protected ports) provides L2 isolation between clients in the same 

VLAN. Supports multiple uplinks 

Port Security 

Locks MAC addresses to ports and limits the number of learned MAC address 

Summary of Contents for SM8TAT2SA

Page 1: ...SM8TAT2SA SM16TAT2SA and SM24TAT2SA Smart Managed Switches 8 16 24 Port Gigabit PoE 2 Port 100 1000 SFP Slots Install Guide Part Number 33716 Revision L June 2022...

Page 2: ...undertakes no obligation to update the information in this publication Lantronix does not make and specifically disclaims all warranties of any kind express implied or otherwise regarding title non i...

Page 3: ...Warning Equipment grounding is vital to ensure safe operation The installer must ensure that the power module is properly grounded during and after installation Failure to observe this warning could r...

Page 4: ...de Reset Button 15 Chapter 3 Installation 16 Package Contents 16 Mounting the Switch on a Wall 16 Mounting the Switch on Desk or Shelf 17 Mounting the Switch in a 19 inch Rack 17 Installing SFP Module...

Page 5: ...02 3af at Power over Ethernet PoE Auto Power Reset and Always on PoE IEEE 802 3az EEE Energy Efficient Ethernet standard for Green Ethernet Support Jumbo Frame up to 9K bytes RADIUS TACACS Authenticat...

Page 6: ...0 1000 SFP Slots Includes 19 rack mount brackets and country specific power cord SM24TAT2SA Smart Managed PoE layer 2 Switch with 52Gbps switching capacity and Smart management Web GUI SNMP Telnet CLI...

Page 7: ...s simultaneously Each of ports 1 8 support PoE PoE within available PoE Power SM16TAT2SA Max PoE budget 250 Watts 30 Watts for 8 ports simultaneously 15 4 Watts for 16 ports simultaneously Each of por...

Page 8: ...traffic to only the requesters Supports 1024 multicast groups IGMP Querier IGMP querier is used to support a Layer 2 multicast domain of snooping switches in the absence of a multicast router IGMP Pro...

Page 9: ...EEE 802 1ab LLDP Used by network devices for advertising their identities capabilities and neighbors on an IEEE 802ab local area network Support LLDP MED extensions Web GUI Built in switch configurati...

Page 10: ...rom misuse of the PDs Always on PoE Always On PoE soft reboot allows a warm reboot of the switch without affecting the PoE output to the PD providing continuous power even during firmware upgrade Abou...

Page 11: ...witch including descriptions of Front and Back Panels Reset the switch or to restore the switch to factory defaults Mode Reset button operation and functions Front and Back Panels The front panels are...

Page 12: ...Lantronix SMxTAT2SA Install Guide 33716 Rev L https www lantronix com 12 Figure 3 SM24TAT2SA Front and Back Panels...

Page 13: ...us LEDs Indicate the current status of each port You can check these LEDs to understand the port status in different modes after changing the mode by pressing the Mode Reset button The LED indicators...

Page 14: ...er Blinking The port is transmitting receiving packets and the connection speed is 10 100Mbps Off The port has no active network cable connected or it is not established a link to connected device Oth...

Page 15: ...evious configuration settings saved The First Time Wizard displays again after pressing the Reset button Restore the Switch to Factory Defaults to restore the original factory default settings back to...

Page 16: ...ted to install a surge protector or surge suppressor to protect the switch Compliant with 802 3at in Environment A when using an isolated power supply For 802 3at Environment B applications i e buildi...

Page 17: ...Mounting the Switch in a 19 inch Rack Step 1 Attach the mounting brackets to both sides of the chassis Insert screws and tighten then with a screwdriver to secure the brackets Figure 7 Attaching Brack...

Page 18: ...tion The Fiber Optic Association Inc is an international non profit educational association chartered to promote professionalism in fiber optics through education certification and standards Step 1 In...

Page 19: ...e Country Code extension to the end of the SKU e g SM8TAT2SA NA North America LA Latin America EU Europe UK United Kingdom SA South Africa JP Japan OZ Australia BR Brazil Step 1 Connect the AC power c...

Page 20: ...tch To change the PC s IP address for a PC running Windows 7 8 x 10 is as follows a Type network and sharing into the Search box in the Start Menu b Select Network and Sharing Center c Click on Change...

Page 21: ...temporary internet files Check your PC settings again and repeat step 2 6 Enter the factory default username and password in login page 7 Click Login to log into the switch Note The factory default U...

Page 22: ...ng operating temperature range and take corresponding actions to resolve Port Status LED is Off in Link Act Speed Mode The port is not connected or the connection is not working 1 Check if the cable c...

Page 23: ...e strongly suggested to install a surge protector or surge suppressor to protect the switch The switch is compliant with 802 3at in Environment A when using an isolated power supply For 802 3at Enviro...

Page 24: ...l as possible regarding the symptom including any system messages from the PoE switch For example does a PD not power up at all or does it power up briefly and then power down 2 Determine if the troub...

Page 25: ...ect an overcurrent threshold and disconnect power from the line This prevents excessive current from being delivered by the PoE port which could possibly result in damage to port level components 15 A...

Page 26: ..._______________________ A description of any action s already taken to resolve the problem e g changing mode rebooting etc _____________________________________________________________________________...

Page 27: ...ns This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le pr sent...

Page 28: ...ce Standard IEC62368 1 UL Listed Normas Oficiales Mexicans NOM SMxTAT2SA Summary of compliance with National Differences Standard IEC62368 1 This product fulfils the requirements of IEC62368 1 The equ...

Page 29: ...worden ge nstalleerd S curit lectrique IMPORTANT Cet quipement doit tre utilis conform ment aux instructions de s curit S hk turvallisuus T RKE T m laite on asennettava turvaohjeiden mukaisesti Sicure...

Page 30: ...ve Suite100 Irvine CA 92618 USA Toll Free 800 526 8766 Phone 949 453 3990 Fax 949 453 3995 Technical Support 1 952 358 3601 1 800 260 1312 or https www lantronix com technical support Sales Offices Fo...

Reviews: