Lantronix
SISGM1040-284-LRT Install Guide
33808 Rev. E
12
ConsoleFlow and LPM
ConsoleFlow
•
Auto-discovery of devices connected to the switch interfaces
•
Perform on-demand backup and restore of device configuration
•
Perform secure remote device firmware upgrades
•
Lantronix-hosted public cloud offering
LPM
Lantronix Provisioning Manager allows easy administration of Lantronix devices.
LPM lets you quickly update firmware, update configuration, and provision one or
more devices simultaneously.
MTBF
GB, GC - Ground Benign, Controlled 25°C
951,258 Hrs.
GB, GC - Ground Benign, Controlled 75°C
193,332 Hrs.
DC Power Consumption
*
Measured DC power consumption after 60 minutes under full loading with wire speed forwarding.
12 VDC Input
Device Status
Operation
Interface
DC Current
Consumption
(A)
DC Voltage
(V)
DC Power Consumption (W)
Non-loading
None
0.43
12
5.16
Standby mode
1G TP Port x 8
1G SFP Port x 4
0.77
12
9.24
Full-loading
60 minutes later
1G TP Port x 8
1G SFP Port x 4
0.79
12
9.48
24 VDC Input
Device Status
Operation
Interface
DC Current
Consumption
(A)
DC Voltage
(V)
DC Power Consumption (W)
Non-loading
None
0.22
24
5.28
Standby mode
1G TP Port x 8
1G SFP Port x 4
0.37
24
8.88
Full-loading
60 minutes later
1G TP Port x 8
1G SFP Port x 4
0.38
24
9.12