4.4.2 TCP Client Mode
In TCP Client Mode, the device can establish a TCP connection with the server by the method you set (Startup or
Any Character). After the data has been transferred, the device can disconnect automatically from the server by
using the TCP alive check time or idle timeout settings.
Label
Description
Data Encryption
Click on the radio button to enable or disable data encryption.
Destination Host
Set the IP address of host and the port number of data port.
Idle Timeout
When serial port stops data transmission for a defined period of
time, the connection will be closed and the port will be freed and try
to connect with other hosts.
0
indicate disable this function.
Factory default value is
0
. If Multilink is configured, only the first host
connection is effective for this setting.
Alive Check
The serial device will send TCP alive-check packages in each
defined time interval to remote host to check the TCP connection.
If the TCP connection is not alive, the connection will be closed and
the port will be freed.
0
indicate disable this function. Factory default
is
0
.
Connect on Startup
The TCP Client will build TCP connection once the connected serial
device is started.
Connect on Any Character
The TCP Client will build TCP connection once the connected serial
device starts to send data.