![Lantronix PremierWave Enterprise Wi-Fi 2050 User Manual Download Page 10](http://html.mh-extra.com/html/lantronix/premierwave-enterprise-wi-fi-2050/premierwave-enterprise-wi-fi-2050_user-manual_675659010.webp)
2: Evaluation Kit
PremierWave® 2050 Enterprise Wi-Fi® IoT Module Evaluation Kit User Guide
10
Ref Des.
Connector/Header Function
JP13
Serial Port 2 RS232/RS422/RS485 Mode Jumper
Leave open for RS232 mode. Install for RS422/RS485
JP14
Serial Port 2 RS422/RS485 Mode Jumper
Leave open for RS232 or 4-wire mode. Install for 2-wire mode.
JP15, JP16
USB Host Power Enable Headers
Leave open to enable USB host port power. Install Jumper to turn off host port power.
JP17
USB Host Port Over Current Header
Provides a connection point to the USB host port over-current current flags
JP18
Serial Debug RX Header
Install to connect the serial debug port receive line to the USB to serial converter on J10
JP19
Serial Debug TX Header
Install to connect the serial debug port transmit line to the USB to serial converter on J10
SW1
Module Hardware Reset
When pushed asserts the PremierWave 2050 module hardware reset to reboot the module.
SW2
Module Reset to Default
When pushed asserts the PremierWave 2050 module reset to default function.
SW3
WAKE Button
When pushed asserts the PremierWave 2050 module WAKE signal. Functional for
PremierWave 2050 module only.
Serial Ports 1 and 2 RS232/RS485/RS422 Connections
The evaluation board has two multiprotocol RS-232/RS422/RS485 ports for connection to the
PremierWave 2050 internal UARTs. Serial port 1 is a DB9 type connector labeled J6. Serial
port 2 is a DB9 type connector labeled J7. A null modem cable can be used to connect J6 and
J7 directly to a standard PC RS232 serial port.
The tables below list the RS232/RS422/RS485 signals and corresponding pins on the
evaluation board DB9 connectors. All signals at J6 and J7 are level-shifted by a multiprotocol
transceiver.
Table 2-2 RS-232 Signals on J6 and J7 Serial Ports
PremierWave 2050 Evaluation Board
PIN FUNCTION SERIAL PORTS
DB9 Pin #
TX_232 (Data Out)
3
RX_232 (Data In)
2
CTS_232 (HW Flow Control Input)
8
RTS_232 (HW Flow Control Output)
7
DTR_232 (Modem Control Output)
4
DCD_232 (Modem Control Input)
1
GND (Ground)
5