2: Installation
N-FXE-xxx-02 User Guide, 33509 Rev. D
9
Wake on LAN (WoL)
The WoL function on this NIC can recognize a wake-up frame and signal the PC to power up. The default
state of the WoL function is enabled (ON), which means pin 2 and pin 3 on J1 (
3-pin header
) are
connected via a jumper, as shown below.
Cable Specifications
Fiber cable
Bit error rate:
<10-9
Single mode fiber (
recommended
):
9 μm
Multimode fiber (
recommended
):
62.5/125 μm
Multimode fiber (
optional
):
100/140, 85/140, 50/125 μm
N-FXE-ST-02
1310 nm multimode
Fiber optic transmitter power:
min: -19.0 dBm max: -14.0 dBm
Fiber optic receiver sensitivity:
min: -31.0 dBm max: -xx.0 dBm
Link budget:
12.0 dB
N-FXE-SC-02
1310 nm multimode
Fiber optic transmitter power:
min: -19.0 dBm max: -14.0 dBm
Fiber optic receiver sensitivity:
min: -31.0 dBm max: -14.0 dBm
Link budget:
12.0 dB
N-FXE-LC-02
1310 nm multimode
Fiber optic transmitter power:
min: -19.0 dBm max: -14.0 dBm
Fiber optic receiver sensitivity:
min: -32.0 dBm max: -14.0 dBm
N-FXE-MT-02
1300nm multimode (MT-RJ)
Fiber optic transmitter power:
min: -19.0 dBm max: -14.0 dBm
Fiber optic receiver sensitivity:
min: -31.0 dBm max: -14.0 dBm
Link Budget:
12.0 dB
The fiber optic transmitters on the device meet Class I Laser safety requirements per IEC-825/CDRH
standard and comply with 21CRF1040.10 and 21CRF1040.11.