Specifications
Power Specifications
D - 1
D - Specifications
This appendix lists the power requirements, temperature requirements, altitude limitations, and
relative humidity limitations of the MSS.
D.1 Power Specifications
The MSS is supplied with a power cube adaptor that has the following specifications.
Adapter input voltage:
110 Volts AC domestic
220 Volts international
Adapter output voltage:
6 Volts DC at 700 mA
Operating current:
700 mA at 6 Volts
Power consumption:
4.2 Watts (maximum)
D.2 Temperature Limitations
Operating range:
5˚ to 50˚C (41˚ to 122˚ F)
Storage range:
-40˚ to 66˚C (-40˚ to 151˚F)
Max temperature change/hr:
20˚C (36˚F)
NOTE:
Rapid temperature changes may affect operation. Do not operate the MSS near
heating or cooling devices, large windows, or doors that open to the outdoors.
D.3 Relative Humidity Limitations
Operating range:
10% to 90% (noncondensing)
40% to 60% recommended
Storage range:
10% to 90% (noncondensing)
D.4 Altitude Limitations
Operating:
2.4 km (8,000 ft)
Storage:
9.1 km (30,000 ft)
If you are operating the MSS above 2.4 km (8,000 ft), decrease the operating temperature rating by
1.8˚C for each 1,000 m (1˚F for each 1,000 ft).