3: EMG 8500 Installation
EMG™ Edge Management Gateway User Guide
47
Warning:
The EMG must be powered off when installing or replacing the modules.
Not powering off the device before changing the module will void the
manufacturer warranty.
Figure 3-10 Sample Connectivity Module Configuration (Back Side)
Connecting Terminals
The console port is for local access to the EMG and the attached devices. You may attach a dumb
terminal or a computer with terminal emulation to the console port. The EMG console port uses
RS-232C protocol and supports VT100 emulation. The default serial settings are:
9600 baud
8 bit data
No parity
1 stop bit
No flow control
To connect the console port to a terminal or computer with terminal emulation, Lantronix offers
optional adapters that provide a connection between an RJ45 jack and a DB9 or DB25 connector.
The console port is configured as DTE (non-reversed RJ45). See
To connect a terminal:
1. Attach the Lantronix adapter to your terminal (typically a PN 200.2066A adapter - see
) or your PC's serial port (use PN 200.2070A adapter - see
).
2. Connect the Cat 5 cable to the adapter, and connect the other end to the EMG console port.
3. Turn on the terminal or start your computer's communication program (e.g., PuTTY or
TeraTerm Pro).
4. Once the EMG is running, press
Enter
to establish connection. You should see the model
name and a login prompt on your terminal.
5. Log in with the default user name
sysadmin
and the last 8 characters of the Device ID (for
newly manufactured units that come installed with 8.2.0.1 or later) or
PASS
(for all older units)
as the password.
Bay 1(empty) Bay 2 Ethernet/SFP
Web Manager
Dashboard
Summary of Contents for EMG 7500
Page 100: ...7 Networking EMG Edge Management Gateway User Guide 100 Figure 7 5 Network Wireless Settings ...
Page 353: ...15 Maintenance EMG Edge Management Gateway User Guide 353 Figure 15 12 About EMG ...
Page 474: ...EMG Edge Management Gateway User Guide 474 Figure E 3 EU Declaration of Conformity ...
Page 475: ...EMG Edge Management Gateway User Guide 475 Figure E 4 EU Declaration of Conformity continued ...