12: Maintenance
SLB™ Branch Office Manager User Guide
228
2. Enter the following:
Internal Temperature
Site Information
SLB Firmware
Reboot
Select this option to reboot the SLB branch office manager immediately. The
default is
No
.
Note:
The front panel LCD displays the “Rebooting the SLB” message, and the
normal boot sequence occurs.
Shutdown
Check this option to shut down the SLB. The default is
Unchecked
.
Current
Displays current temperature.
Low (°C)
Sets the acceptable minimum for the internal temperature of the SLB unit. If the
temperature of the SLB device changes to be outside of this range, the SLB
branch office manager will issue an SNMP trap.
High (°C)
Sets the acceptable maximum for the internal temperature of the SLB unit. If the
temperature of the SLB branch office manager changes to be outside of this
range, the SLB device will issue an SNMP trap.
Calibrate Offset (°C)
An offset for calibrating the internal temperature of the SLB unit. The offset will be
applied one hour after setting the calibration value. Zeroing the offset will take
effect immediately and will cancel any current and/or pending calibration.
Data Center Rack Row
Set these fields to define the rack row the SLB unit is located within a large data
center. The default for these fields is 1.
Data Center Rack
Cluster
Set these fields to define the rack cluster the SLB device is located within a large
data center. The default for these fields is 1.
Data Center Rack
Set these fields to define the rack the SLB unit is located within a large data
center. The default for these fields is 1.
Site Tag
Tag or description used to identify the location or some other attribute of the SLB
Current Version
Displays the current firmware version.
Update Firmware
To update the SLB firmware, select the checkbox. If you select this option, the
SLB branch office manager reboots after you apply the update. The first time
boot for each bank may take up to 5 minutes. Subsequent boot times will be
approximately 2 minutes.
To view a log of all prior firmware updates, click the
Firmware Update Log
link.
Note:
For dual boot SLB units, the non-active boot bank is updated during the
firmware update, without requiring a reboot. The configuration on the current boot
bank may optionally be copied to the non-active boot bank during the firmware
update. For both single boot and dual boot SLB units, prior to firmware update, the
current configuration is saved to the Local Disk location with the name
"before_MMDDYY_HHMM".
Firmware Filename
The name of the firmware update file downloaded from the Lantronix web site.
Key
A key for validating the firmware file. The key is provided with the firmware file
(32 hex characters).