9: USB Port
SLB™ Branch Office Manager User Guide
178
IP Settings
4. Click
Apply
.
Enable NAT
Select to enable Network Address Translation (NAT) for dial-in and dial-out
PPP connections on a per modem (device port or USB port) basis. Users
dialing into the SLB unit access the network connected to Eth1 and/or Eth2.
Note:
IP forwarding must be enabled on the Network > Network Settings
(bottom of page) page for NAT to work. See
Chapter 6: Basic Parameters on
.
Dial-out Number
Phone number for dialing out to a remote system or serial device. May have up
to 20 characters. Any format is acceptable.
Remote/Dial-out Login
User ID for dialing out to a remote system. May have up to 32 characters.
Remote/Dial-out Pwd
Enter password for dialing out to a remote system. May have up to 64
characters.
Retype
Re-enter password for dialing out to a remote system.May have up to 64
characters.
Restart Delay
The number of seconds after the timeout and before the SLB branch office
manager attempts another connection. The default is
30
seconds.
CBCP Server Allow
No Callback
For CBCP Server state, allows "No Callback" as an option in the CBCP
handshake in addition to User-defined Number and Admin-defined Number.
CBCP Client Type
For CBCP Client, this selects the number that the client would like to use for
callback - either a user-defined number passed to the server (specified by the
Fixed Dial-back Number) or an administrator-defined number determined by
the server based on the login that is PAP or CHAP authenticated.
Service
The available connection services for this modem port (Telnet, SSH, or TCP).
Only one can be active at a time. The default is None.
Telnet Port
Telnet Port Telnet session port number to use if you selected Telnet.
Defaults:
USB Port U1:
2049
USB Port U2:
2050
Range:
1025-65535
SSH Port
The SSH session port number to use if you selected SSH.
Defaults:
USB Port U1:
3049
USB Port U2:
3050
Range:
1025-65535
TCP Port
The TCP (raw) session port number to use if you selected TCP.
Defaults:
USB Port U1:
4049
USB Port U2:
4050
Range:
1025-65535
Authenticate
(checkbox)
If selected, the SLB unit requires user authentication before granting access to
the port.
Authenticate
is selected by default for
Telnet Port
and
SSH Port
, but
not for
TCP Port
.
Summary of Contents for 100-120 VAC SLB