background image

 

 

 

IPES/IES-0208 Series 

8 10/100TX+ 2 10/100/1000T or 1000FX (w/8 PoE at/af) IP67/IP54 

rated Industrial Unmanaged Switch 

 

      User Manual 

 

 

 

IPES-0208GF-67 

 

 

 

  IPES-0208T-67 

 

Aug  2021 

Summary of Contents for IPES-0208 Series

Page 1: ...IPES IES 0208 Series 8 10 100TX 2 10 100 1000T or 1000FX w 8 PoE at af IP67 IP54 rated Industrial Unmanaged Switch User Manual IPES 0208GF 67 IPES 0208T 67 Aug 2021...

Page 2: ...y an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where la...

Page 3: ...consent of Lantech Communications Global Inc Products offered may contain software which is proprietary to Lantech Communications Global Inc The offer or supply of these products and services does no...

Page 4: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...

Page 5: ...Content Chapter 1 Introduction 5 Chapter 2 Hardware Description 6 2 1 Physical Dimension 6 2 2 Package Content 8 2 3 IP Protection 8 2 4 LED Indicators 11 Chapter 3 Hardware Installation 12...

Page 6: ...ed protection which meets the high reliability requirements demanded by industrial rolling stock applications Model List IPES 0208GF 8 10 100TX 2 1000FX w 8 PoE at af Industrial Unmanaged Switch IES 0...

Page 7: ...ysical Dimension Aluminum case IP 67 IPES 0208GF 215mm W x185mm H x91 2mm D IES 0208GF 215mm W x192 5mm H x76 7mm D IPES 0208T 215mm W x185mm H x91 2mm D IES 0208T 215mm W x185mm H x71mm D Aluminum ca...

Page 8: ...7 Port description of IP67 rated switch The port description of IP54 model is the same as of IP67 one...

Page 9: ...Electrotechnical Commission IEC Solid particle protection The first digit indicates the level of protection that the enclosure provides against access to hazardous parts e g electrical conductors mov...

Page 10: ...Test duration 10 minutes Water equivalent to 1 mm rainfall per minute 2 Dripping water when tilted up to 15 Vertically dripping water shall have no harmful effect when the enclosure is tilted at an a...

Page 11: ...gress of water in harmful quantity shall not be possible when the enclosure is immersed in water under defined conditions of pressure and time up to 1 m of submersion Test duration 30 minutes Immersio...

Page 12: ...g table provides the description of the LED status and their meanings for the switch LED Color Status Meaning PWR1 Green On Power 1 is active Off Power 1 is inactive PWR2 Green On Power 2 is active Of...

Page 13: ...d converter should be used in between the train power supply and the switch 3 1 1Unpack switch and check the accessory with packing content list 3 1 2 Mount the switch on desired position For the best...

Page 14: ...th 802 3af at standardized devices Please make sure that the external power supply unit you use to provide the PoE voltage meet the following criteria The output voltage of power supply must exceed 48...

Page 15: ...y A break in contact is reported via the relay contact The failure of at least one of the two supply voltages The break link status of at least one switch port 3 1 4 Fitting the device grounding Insta...

Page 16: ...15 Ground screw of I P ES 0208 switch 3 1 5 Connect the M12 connector with RJ 45 data cable ports are not used shall be caped that comes with the package to insulate the surrounding...

Page 17: ...16 Pin assignment of M12 10 100Tx network connector Pin assignment of M12 10 100 1000T network connector...

Page 18: ...ly achieved when bolted together The other components attaching to the system have to meet with the IP67 IP54 protection class in order to reach the whole system IP67 IP54 protection Empty ports must...

Reviews: