background image

 

 

Lantech

 

IPES-0008A-12V 

8 10/100TX w/ 8 Booster PoE at/af 

Injector Industrial Switch 

User Manual 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

V1.00 

Jun 2010

Summary of Contents for IPES-0008A-12V

Page 1: ...Lantech IPES 0008A 12V 8 10 100TX w 8 Booster PoE at af Injector Industrial Switch User Manual V1 00 Jun 2010 ...

Page 2: ...oy an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where large inductive loads such as motors or contactors are in close vicinity to the camera or its cable It is also mandatory to use an STP cable where the power device like IP camera is used outdoors or wh...

Page 3: ...t occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipme...

Page 4: ... Description 5 Physical Dimension 5 Front Panel 6 Top View 6 LED Indicators 7 Ports 8 Cabling 9 Wiring the Power Inputs 10 Wiring the Fault Alarm Contact 12 Mounting Installation 13 DIN Rail Mounting 13 Wall Mounting 15 Hardware Installation 16 Installation Steps 16 Network Application 17 Troubleshooting 18 ...

Page 5: ...o receive power as well as data over an RJ 45 cable Features System Interface Performance RJ 45 ports support Auto MDI MDI X Function Embedded 4 port PoE Injection Store and Forward Switching Architecture Back plane Switching Fabric 1 6Gbps 2K MAC Address Table Power Input DC 12V 48V Redundant Power Input Operating Temperature Wide Operating Temperature 40 C 75 C Case Installation IP 30 Protection...

Page 6: ... Relay LED Indicators Unit Power1 Power2 P Fail PoE Ethernet port Link Active Speed PoE Power Output Per port 48 VDC 15 4 Watts Pin Assignment RJ 45 port 1 4 support IEEE 802 3af End point Alternative A mode Positive VCC RJ 45 pin 1 2 Negative VCC RJ 45 pin 3 6 Data 1 2 3 6 Power Power Consumption 10 Watts Max POE Power Budget 240 Watts 48V input 90W 12V 120W 24V input Power Input External Power S...

Page 7: ...s Environment Operating Temperature Standard 20 C 60 C 4 F 140 F E models 40 C 75 C 40 F 167 F Operating Humidity 5 95 non condensing Storage Temperature 40 85o C Storage Humidity 5 95 non condensing Certifications EMC FCC Class A CE EN61000 6 2 CE EN61000 6 4 CE EN61000 4 2 ESD CE EN61000 4 3 RS CE EN61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6 CS CE EN61000 4 8 Magnetic Field Free Fall IEC6...

Page 8: ...Removable Terminal Block Optional Wall mount Kit 2 wall mount bracket with screws Compare the contents of the industrial switch with the standard checklist above If any item is damaged or missing please contact the local dealer for service Safety Precaution Attention IF DC voltage is supplied by an external circuit please use a protection device on the power supply input ...

Page 9: ...l switch s hardware specs ports cabling information and wiring installation will be described Physical Dimension IPES 0008A 12V Industrial Switch dimensions W x D x H is 48 6mm x 95mm x 140mm the detail dimensions as Figure 1 Figure 1 Mechanical Dimensions ...

Page 10: ...2 Front Panel of the PoE Injectors Industrial Switch Top View The top view of IPES 0008A 12V Industrial Switch has one terminal block connector of two DC power inputs and Relay circuit contact Please refer to Figure 3 for further information Figure 3 Top View of the PoE Injectors Industrial Switch ...

Page 11: ... 2 is active Off Power input 2 is inactive P Fail Red On Power input 1 or 2 has failed Off Power input 1 and 2 are both functional or no power inputs PoE indicator Port 1 4 Green On The port is supplying power to the powered device Off No powered device attached or power supplying fails LAN Port 1 8 RJ 45 Green On Connected to network Flashing Networking is active Off Not connected to network Gree...

Page 12: ... on this industrial switch supports automatic MDI MDI X operation users can use straight through cables See figures below for all network connections to PCs or Servers or to other switches hubs In straight through cable pins 1 2 3 and 6 at one end of the cable are connected straight through to pins 1 2 3 and 6 at the other end of the cable Table 3 shows the 10BASE T 100BASE TX MDI and MDI X port p...

Page 13: ...Switch Switch 3 TD 3 RD 6 TD 6 RD 1 RD 1 TD 2 RD 2 TD Figure 5 Crossover Cable Schematic Cabling Twisted pair segments can be connected with unshielded twisted pair UTP or shielded twisted pair STP cable The cable must comply with the IEEE 802 3u 100Base TX standard e g CAT 5 CAT 5e or CAT 6 The cable between the equipment and the link partner switch hub workstation etc must be less than 100 meter...

Page 14: ... V V contacts on the terminal block connector as shown in Figure 6 Figure 6 Terminal Block Front View for Power1 Power2 Contact 2 Tighten the wire clamp screws which as shown in the Figure 7 for preventing the wires from loosing Figure 7 Terminal Block Top View Note Use Copper Conductors Only 60 75 C Tighten to 5 lb in The wire gauge for the terminal block should be in the range between 12 24 AWG ...

Page 15: ...11 Power Restriction under 48VDC power IPES 0008A 12V only can support one 48VDC power source If using two 48VDC power source IPES 0008A 12V may cause damage ...

Page 16: ...strial switch only and from a Normally Close circuit Please refer to Figure 8 for the fault alarm contact and Figure 9 shows the application example for the fault alarm operation Figure 8 Terminal Block Front View for Fault Alarm Contact Figure 9 Fault Alarm Application Example Note Use Copper Conductors Only 60 75 C Tighten to 5 lb in The wire gauge for the terminal block should be in the range b...

Page 17: ... is not screwed on the switch please refer to Figure 10 to screw it on the switch Follow the steps below to hang the industrial switch Figure 10 Rear side of the PoE Injectors Industrial Switch 1 Use the screws to screw the DIN Rail bracket on the rear side of the industrial switch 2 To remove the bracket reverse the step 1 DIN Rail Bracket ...

Page 18: ...switch insert the top of the bracket into the rail as Figure 11 Figure 11 4 Then lightly pull down the bracket into the rail as shown in Figure 12 Figure 12 5 Check if the bracket is tightened on the rail or not 6 To remove the switch from the rail reverse steps above ...

Page 19: ... the switch loose the screws to remove it 2 Place the wall mount bracket on the top side and bottom side of the switch 3 Use the screws to screw the wall mount bracket on the switch 4 Use the hook holes at the corners of the wall mount bracket to hang the industrial switch on the wall 5 To remove the wall mount bracket reverse steps above Figure 13 Wall Mount Bracket Installation Figure 14 Wall Mo...

Page 20: ...o the Mounting Installation section 4 Power on the Industrial switch Please refer to the Wiring the Power Inputs section for knowing the information about how to wire the power cord The power LED on the Industrial switch will light up Please refer to the LED Indicators section for indication of LED lights 5 Prepare the twisted pair straight through CAT 5 above cable for Ethernet connection 6 Inser...

Page 21: ...egment provides the sample to help user have more actual idea of industrial switch application For a sample application of the industrial switch see the Figure 15 below Figure 15 Network Application IPES 0008A 12V Industrial Switch ...

Page 22: ...f any twisted pair connection does not exceed 100 meters 328 feet Diagnosing LED Indicators To assist in identifying problems the Switch can be easily monitored through LED indicators on the front panel which describe common problems the user may encounter and where the user can find possible solutions If the power indicator does not light on when the power cord is plugged in user may have a probl...

Reviews: