background image

 

 

 

IPGS-5400-2P 

IGS-5400-2P 

4 Modular Slots Industrial L2+ Managed (PoE) Switch w/ITU 

G.8032 Ring

 

 

User Manual (Hardware) 

 

   

 

 

 

                                                                     

 

 

 

 

 

 

 

 

 

 

 

 

 

 

May.  2016 

Summary of Contents for IGS-5400-2P

Page 1: ...IPGS 5400 2P IGS 5400 2P 4 Modular Slots Industrial L2 Managed PoE Switch w ITU G 8032 Ring User Manual Hardware May 2016...

Page 2: ...y an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where la...

Page 3: ...consent of Lantech Communications Global Inc Products offered may contain software which is proprietary to Lantech Communications Global Inc The offer or supply of these products and services does no...

Page 4: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...

Page 5: ...tion 13 Hardware installation 13 3 1 Rack Mounting 14 3 2 Wiring the Power Inputs 16 3 3 Wiring the Fault Alarm Contact 19 3 4 Cabling 20 3 5 USB Dongle 23 Chapter 4 Network Application 24 ITU G 8032...

Page 6: ...IEEE 802 1Q VLAN IEEE 802 1p Class of Service IEEE 802 1X Access Control IEEE 802 1D Spanning Tree IEEE 802 1w Rapid Spanning Tree IEEE 802 1s Multiple Spanning Tree IEEE 802 3ad Link Aggregation Cont...

Page 7: ...on Yellow MINI GBIC Link Activity Green Power Supply IGS 5400 2P 1 built in power 1 optional power IPGS 5400 2P 1 built in power 1 optional power 1 PoE power VAC VDC isolated 4000V 85V 265VAC 100 370V...

Page 8: ...Humidity 5 95 Non condensing Operating Temperature 20 C 60 C Storage Temperature 40 C 85 C EMI FCC Class A CE EN61000 4 2 ESD CE EN61000 4 3 RS CE EN 61000 4 4 EFT CE EN61000 4 5 Surge CE EN61000 4 6...

Page 9: ...2 Hardware Description In this paragraph it will describe the Industrial switch s hardware spec port cabling information and wiring installation 2 1 Physical Dimension Metal case IP 30 440 W x 325 D...

Page 10: ...t access to hazardous parts e g electrical conductors moving parts and the ingress of solid foreign objects Level Object size protected against Effective against 0 No protection against contact and in...

Page 11: ...est duration 10 minutes Water equivalent to 3 mm rainfall per minute 3 Spraying water Water falling as a spray at any angle up to 60 from the vertical shall have no harmful effect Test duration 5 minu...

Page 12: ...f at least 1 m measured at bottom of device and at least 15 cm measured at top of device 8 Immersion beyond 1 m The equipment is suitable for continuous immersion in water under conditions which shall...

Page 13: ...ive Off Power 1 is inactive PWR2 Green On Power 2 is active Off Power 2 is inactive FAULT Red On Power or port failure Off No failure RJ 45 Link Ack On A network device is detected Blinking The port i...

Page 14: ...ion about how to wire the power The power LED on the Industrial switch will light up 5 Prepare the twisted pair straight through Category 5 cable for Ethernet connection 6 Insert one side of RJ 45 cab...

Page 15: ...quipment rack brackets included with the switch Cross head screwdriver not provided Four standard equipment rack screws not provided Perform this procedure to install the switch in a 19 inch equipment...

Page 16: ...15...

Page 17: ...S 5400 2P power input 3 is separated with power of switch system power input 1 and 2 The power input module 2 is an optional part There are 4 kinds of power input modules for switch system can be chos...

Page 18: ...hen insert DC power wires into the contacts V and V of power module 3 For the power module EOTH000704 install the power module then insert DC power wires into the contacts V and V of power module 4 Ti...

Page 19: ...ires into the contacts and for power 3 for PoE Only for IPGS 5400 2P 7 Tighten the wire clamp screws for preventing the wires from loosing NOTE The wire gauge for the terminal block should be in the r...

Page 20: ...e switch will detect the fault status of the power failure or port link failure available for managed model and then forms an open circuit The following illustration shows an application example for w...

Page 21: ...tor pluggable SFP is a compact optical transceiver used in optical communications for both telecommunication and data communications The SFP slots supporting Gigabit speed up to 1000Mbps They are used...

Page 22: ...21 Transceiver Inserted Second insert the fiber cable of LC connector into the transceiver LC connector to the transceiver...

Page 23: ...follow the steps shown below First press the upper side of the LC connector to release from the transceiver and pull it out Remove LC connector Second push down the metal loop and pull the transceive...

Page 24: ...guration from web browser or other user interface When you plug USB dongle in switch the switch will backup its configuration file automatically the backup file will be named cfgexport_ switch MAC yml...

Page 25: ...munication Unit G 8032 v2 draft The benefits of G 8032 are 1 50ms recovery time when failover 2 G 8032 has defined the protocol scheme parameters functions test measures to be unified that the users c...

Page 26: ...25 Multiple Rings...

Page 27: ...26 Dual Homing Chain...

Page 28: ...27...

Page 29: ...cable which one end is DB9 female connector and the other end is DB9 male connector Attach the end of DB9 female connector to PC or terminal and the other end of DB9 male connector to the console port...

Page 30: ...f the console port Baud Rate 115200 bps Data Bits 8 Parity none Stop Bit 1 Flow control None The settings of communication parameters Having finished the parameter settings click OK When the blank scr...

Page 31: ...30 Console login interface Notice For web based management please refer to our Software Management Manual at http www lantechcom tw global eng support downloads html...