background image

 

 

Lantech 

 

IGC-0101DSFP 

IPGC-0101DSFP 

10/100/1000T (PoE at) to 100/1000M 

SFP Industrial Switch Converter 

 

 

User Manual

 

 

 

 

 

Oct  2020 

Summary of Contents for IGC-0101DSFP

Page 1: ...Lantech IGC 0101DSFP IPGC 0101DSFP 10 100 1000T PoE at to 100 1000M SFP Industrial Switch Converter User Manual Oct 2020...

Page 2: ...y an STP network cable in demanding electrical environments Examples of demanding indoor environments are where the network cable is located in parallel with electrical mains supply cables or where la...

Page 3: ...SFP 2 Packing List 3 Safety Precaution 3 Hardware Description 4 Front Panel 4 Top View 5 Wiring the Power Inputs 5 Wiring the Fault Alarm Contact 6 LED Indicators 7 DIP Switch 7 Ports 8 Cabling 9 Moun...

Page 4: ...Rack mounting 16 Hardware Installation 18 Installation Steps 18 Troubles shooting 20...

Page 5: ...occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encourage...

Page 6: ...input from 18V 72VDC 18 36VAC with galvanic isolation IGC 0101DSFP supports dual wide range input from 18V 72VDC standard model and 18 36VAC AC model with galvanic isolation that is good for various...

Page 7: ...LED and relay alarm can be off by DIP switch Dual DC input power IPGC 0101DSFP supports dual input from 9 5V 57VDC 12V model or 44V 56VDC 48V model for various application including vehicle railway so...

Page 8: ...st 1 x 10 100 1000 to Mini GBIC Industrial Switch Converter 1 x Terminal Block Safety Precaution Attention IF DC voltage is supplied by an external circuit please use a protection device on the power...

Page 9: ...we will introduce the Industrial switch converter s hardware spec port cabling information and wiring installation Front Panel The Front Panel of the IGC 0101DSFP IPGC 0101DSFP is shown as below Front...

Page 10: ...ne terminal block connector of two DC power inputs Top panel of the Industrial Switch Converter Wiring the Power Inputs Please follow the steps below to insert the power wire 1 Insert the positive and...

Page 11: ...iddle of terminal block connector as the picture shows below Inserting the wires it will detect the fault status which the power is failure or port link failure for managed model and form an open circ...

Page 12: ...n Power input 1 or 2 has failed Off Power input 1 and 2 are both functional or no power input LNK ACT fiber port Green On Connected to network Flashing Networking is active Off Not connected to networ...

Page 13: ...All ports on this industrial switch converter support automatic MDI MDI X operation you can use straight through cables See Figure below for all network connections to PCs or servers or to other swit...

Page 14: ...ector type must use 9 125 m single mode fiber cable You can connect two devices in the distance of 10 km Fiber segment using multi mode connector type must use 50 125 or 62 5 125 m multi mode fiber ca...

Page 15: ...10 Figure 2 8 Transceiver to the SFP module Figure 2 9 Transceiver Inserted...

Page 16: ...sceiver Figure 2 10 LC connector to the transceiver To remove the LC connector from the transceiver please follow the steps shown below First press the upper side of the LC connector from the transcei...

Page 17: ...12 Second push down the metal loop and pull the transceiver out by the plastic part Figure 2 12 Pull out from the SFP module...

Page 18: ...of factory If the DIN Rail is not screwed on the industrial switch please see the following figure to screw the DIN Rail on the switch Follow the below steps to hang the industrial switch 1 Use the s...

Page 19: ...nsert the top of DIN Rail into the track 4 Then lightly push the button of DIN Rail into the track 5 Check the DIN Rail is tightly on the track 6 To remove the industrial switch from the track reverse...

Page 20: ...from the industrial switch unscrew the screws to remove the DIN Rail clip 2 Place the wall mount plates on the rear panel of the industrial switch 3 Use the screws to secure the wall mount plates on t...

Page 21: ...s L bracket optional for one converter Eight L bracket screws included with the optional L bracket for one converter Cross head screwdriver not provided Four standard equipment rack screws not provide...

Page 22: ...17 3 Have another person hold the whole kit in the equipment rack while you secure it using standard rack mount screws not provided...

Page 23: ...is not screwed on the Industrial switch converter Please refer to DIN Rail Mounting section for DIN Rail installation If you want to wall mount the Industrial switch converter then please refer to Wal...

Page 24: ...side of category 5e or above cables to the network devices Ethernet port RJ 45 port e g switch PC or Server The UTP port RJ 45 LED on the Industrial switch converter will light up when the cable conne...

Page 25: ...r connection does not exceed 100 meters 328 feet Diagnosing LED Indicators To assist in identifying problems the industrial switch converter can be easily monitored through panel indicators which desc...