1 2 3 Manual for Power Supply Voltage range change  

from 100-120VAC to 200-240 VAC 

The 

LP-SG2402FP3x 

is a 24 x 10/100 Mbps 802.3af PoE Ports Switch 

without Mana 2 x 10/100/1000 Mbps Dual Uplink Copper or SFP 

Ports that has a two Input Voltage range power supply.

It  comes  standard  with  the  100-120  VAC  voltage  range  unless  it  was 

ordered from the factory with the desired range.  In this case, it must be 

changed to the 200 to 240 VAC range, when the local mains power voltage 

is between 200 and 240 VAC.

In  order  to  change  the  standard  range  to  the  200  to  240  VAC  range, 

please follow the next steps.

In order to make the range change, the “Warranty Void if Broken” label 

must be broken to access the screw under it. This will void your warranty 

unless  you  ask your preferred LanPro Inc. local  representative  to  make 

this change for you for a nominal charge and replace the warranty label. 

LP-SG2402FP3x 

1 2 3 Manual for Power Supply Voltage 

range change from 100-120VAC  

to 200-240 VAC 

Opening the chassis

1

Summary of Contents for LP-SG2402FP3 Series

Page 1: ...with the desired range In this case it must be changed to the 200 to 240 VAC range when the local mains power voltage is between 200 and 240 VAC In order to change the standard range to the 200 to 240 VAC range please follow the next steps In order to make the range change the Warranty Void if Broken label must be broken to access the screw under it This will void your warranty unless you ask your...

Page 2: ...Series LP SG2402FP3x 1 2 3 Manual for Power Supply Voltage range change from 100 120VAC to 200 240 VAC 2 In order to open the Power Supply Chassis please unscrew three front top screws 6 lateral and 4 back screws Please refer to Figure 1 Figure 1 ...

Page 3: ...ange 2 3 4 Locate the voltage range selector it is on one side of the power supply module as shown in Figure 2 You can change the input power voltage range we suggest that you use the tip of a flat screwdriver to flip the selector switch to the right until the 230 V Range value appears in the window as shown in Figure 3 Please peel off the backing of the replacement new range label and align and a...

Page 4: ...ack Series LP SG2402FP3x 1 2 3 Manual for Power Supply Voltage range change from 100 120VAC to 200 240 VAC 4 Closing the switch chassis 5 Now we can close the chassis again first by aligning the cover Please refer to Figure 5 Figure 4 Figure 5 ...

Page 5: ...but without tightening it will be done once all the screws are in place Once all screws are presented into their sockets carefully tighten them without excessive torque to avoid damaging the threads once done the purpose of this manual is complete Please see Figure 6 Figure 6 LanPro is continuously improving its products and reserves the right to change specifications and availability without prio...

Reviews: