5  Safety Instructions 

5.1  General Safety Instructions 

When using a Langer EMV Technik GmbH product, please observe the following safety instruc-
tions to protect yourself against electric shock or the risk of injury. 
 
The use of the device must be carried out by personnel who are experts in the field of EMC and 
who are suitable for this work under the influence of interference voltages and burst fields (electri-
cal and magnetic). 
 

-

  The operating and safety instructions of all devices used must be observed. 

-

  Damaged or defective devices must not be used. 

-

  Before operating a measuring station with a product of Langer EMV-Technik GmbH, carry out a 

visual inspection. Damaged connecting cables must be replaced before operation. 

-

  The product of Langer EMV-Technik GmbH may only be used for applications for which it is 

intended. Any other use is not permitted. 

 

5.2  Intended Use 

The NNB 21 artificial network is designed for measuring conducted interference emissions from 
electronic assemblies. Measurements can be carried out in the frequency range from 100 kHz to 
100 MHz based on the CISPR 25/ISO 7637 standard. The range has been extended to 1 GHz for 
measurement during development. The NNB 21 is built according to its specified use, therefore it 
must only be used for this purpose. 
 

5.3  Reasonably foreseeable Misuse 

Reasonably foreseeable misuses of the NNB 21 set are: 

-

  Use of the product outside of the given specifications. 

-

  Modification or changing of the product without consent of Langer EMV-Technik GmbH. 

-

  Operating the product with a technical fault. 

 
 

Summary of Contents for NNB 21

Page 1: ..._NNB 21 set_user manual User Manual NNB 21 set Line impedance Stabilization Network Measurement of conducted disturbance emissions Copyright C Dipl Ing Gunter Langer N thnitzer Hang 31 01728 Bannewitz...

Page 2: ...Reading and Understanding the Manual 4 2 3 Local Safety and Accident Prevention Regulations 4 2 4 Images 4 2 5 Limitations of Liability 4 2 6 Errors and Omissions 4 2 7 Copyright 4 3 Scope of Deliver...

Page 3: ...nce Stabilization Network agrees with the regulations of EC guidelines Low Voltage Directive 2014 35 EU EMC Directive 2014 30 EU Restriction of certain Hazardous Substances 2011 65 EU Applied standard...

Page 4: ...lity The Langer EMV Technik GmbH is not liable for personal injury or damage to material if the instructions in this user manual were not followed the product was used by personnel who are not qualifi...

Page 5: ...3 Terminal block 2 polie AK 2 pole 4 04 User manual NNB 21 m 1 05 System Case NNB 21 case 1 Important The scope of delivery may differ depending on the respective order Figure 1 NNB 21 set case 4 Tech...

Page 6: ...H carry out a visual inspection Damaged connecting cables must be replaced before operation The product of Langer EMV Technik GmbH may only be used for applications for which it is intended Any other...

Page 7: ...it frequency of 1 GHz less than 5 cm If both connections of the NNB 21 are used to supply the DUT and the GND switch is open the NNB 21 measures the total current common mode of both lines For a separ...

Page 8: ...processed either in its entirety or in part without the prior written permission of Langer EMV Technik GmbH The management of Langer EMV Technik GmbH assumes no liability for damage that may arise fro...

Reviews: