background image

 

Star Manufacturing International 

10 Sunnen Drive 

St. Louis, MO.63143-3800 

Part Number: 2M-W822 

Ph: 314-781-2777 Fax: 314-781-2714 

 

Rev. B 

WWW.STAR-MFG.COM

 

April 13, 2010 

 

 

 

 

 

 

Installation, Operation,  

Maintenance, & Troubleshooting 

Model:  R60S 

 

Standard Bake Oven Range 

 
 

Summary of Contents for R60S

Page 1: ...national 10 Sunnen Drive St Louis MO 63143 3800 Part Number 2M W822 Ph 314 781 2777 Fax 314 781 2714 Rev B WWW STAR MFG COM April 13 2010 Installation Operation Maintenance Troubleshooting Model R60S...

Page 2: ...LLS GAS THIS INFORMATION SHALL BE OBTAINED BY CONSULTING YOUR LOCAL GAS SUPPLIER AS A MINIMUM TURN OFF THE GAS AND CALL YOUR GAS COMPANY AND YOUR AUTHORIZED SERVICE AGENT EVACUATE ALL PERSONNEL FROM T...

Page 3: ...e Of Contents 3 2 Read First 4 3 Equipment Description 6 4 Unpacking 7 5 Installation 8 6 Initial Start Up 9 7 Operation 10 8 Cleaning Maintenance Procedures 12 9 Troubleshooting 13 10 Exploded View P...

Page 4: ...EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTICE The data plate is located right of the range top controls and circuit breaker door on oven The oven voltage wattage seri...

Page 5: ...e performed by qualified personnel only Consult your Lang Authorized Service Agent Directory You can call our toll free number 1 800 807 9054 or visit our website WWW STAR MFG COM for the service agen...

Page 6: ...by five 850 F Thermostats R60S B Four 12 x24 Hot tops controlled by four 850 F thermostats and two French plates controlled by two 6 heat switches R60S C 24 x24 Griddle controlled by two 450 F thermos...

Page 7: ...nd strapped to a skid Remove the cardboard cover cut the straps and remove the wood frame RANGE WEIGHS 900 LBS 408 kilograms FOR SAFE HANDLING INSTALLER SHOULD OBTAIN HELP AS NEEDED OR EMPLOY APPROPRI...

Page 8: ...any components such as a vent hood grease extractors fire extinguisher systems must conform to their applicable National State and locally recognized installation standards Electrical Connection All...

Page 9: ...he range ovens to saturate until all vapor and condensation has been eliminated For best operating results allow the range ovens to thoroughly dry out Allow 8 to 12 hours for this process Clean top pl...

Page 10: ...and bottom heat to suit the product to be baked or roasted The 12 high Roasting and Baking range ovens is equipped with a removable rack For baking pies bread or for roasting operations the rack may b...

Page 11: ...type 6 heat switch Temperature ranges from 0 F 750 F Recommended Light duty sauce pans and small stockpots Not Recommended Heavy stock pots or heavy urns or kettles 60 x 24 or 48 x 24 or 36 x 24 or 2...

Page 12: ...itary if dirt is allowed to accumulate on it Take advantage of the clean sanitary features of electric equipment Give it the regular attention that it deserves the same as any other highly perfected m...

Page 13: ...ational condition Failed thermostat Verify calibration Product is not cooked Failed 3 heat switch Call factory or consult service manual for correct checks on each switch TESTS NOTICE Service on this...

Page 14: ...ev A 10 05 2010 MODEL R60S Electric 60 Range 26 23 25 24 38 46 39 40 37 44 36 45 1 13 14 16 17 21 20 19 15 35 18 12 3 2 5 4 6 7 8 9 10 11 28 27 29 22 41 42 46 43 34 33 34 32 31 30 OVEN CONTROLS RANGE...

Page 15: ...RANGE PLATE MODULE 1 X 5 R60S ATG 3 GROOVING GRIDDLE GROOVING 4 P9 50300 82 1 1 EGO PLAT FRM ASY PHANT R60S ATB R60S ATC R60S ATD R60S ATF 5 EGO PLAT FRM ASY PHANT R60S ATH 5 2N 11120 12 2 ELMNT TK 20...

Page 16: ...TG 480 480M 2N 11010 26 3 ELMNT T P 380V 1 S 3KW R60S ATD380M 2N 11050 34 4 ELE 360VN 380V 1 S 1 2KW R60S ATB380M 8 2N 11010 09 2 ELMNT T P 208V 3KW O S R60S ATC 208V 3 R60S ATD 208V 4 R60S ATE 208 20...

Page 17: ...1I S 1 2KW R60S ATB380M R60S ATD380M 2N 11050 36 ELE 36OVN 240V I S 1 2KW R60S ATA 240V 17 2N 11050 25 4 ELE 36OVN 240V O S 1 8KW 240V 2N 11050 29 ELMNT 36OVEN 480V 9 C C R60S ATA440M 480M 480V R60S...

Page 18: ...240 480 480M R60S ATH 480 Y9 70701 16 2 KNOB 450 A PHANTOM R60S ATC440M 480M R60S ATD 208 240 380M 480 440M 480M R60S ATE208M R60S ATF 208 240 480 R60S ATG 208 240 480 480M 4 R60S ATE208M R60S ATF 20...

Page 19: ...309 1 HOLE PATTERN A E G 480V R60S ATA 480 R60S ATE480M R60S ATG 480 39 P9 500 312 1 C B DOOR FRAME ASSY R60S ATA 208 R60S ATC 208 40 P9 500 310 2 1 BREAKER COVER HINGE 208 240V 41 2C 20201 13 2 WSHR...

Page 20: ...80M R60S ATE480M IMPORTANT WHEN ORDERING SPECIFY VOLTAGE OR TYPE GAS DESIRED PAGE INCLUDE MODEL AND SERIAL NUMBER OF Some items are included for illustrative purposes only and in certain instances may...

Page 21: ...Wiring Diagram 208 240 Volt 16...

Page 22: ...nge Top Wiring 17 1 Griddle and Top Plate Element 2 Pilot Light 3 450 Griddle thermostat 4 Circuit breakers 5 French plate 6 6 Heat switch 7 Hot Top 8 800 Hot Top thermostat GRIDDLE HOT TOP FRENCH PLA...

Page 23: ...Wiring Diagram 480 Volt 18...

Page 24: ...STAR INTERNATIONAL HOLDINGS INC COMPANY Star Holman Lang Wells Bloomfield Toastmaster 10 Sunnen Drive St Louis MO 63143 U S A 800 807 9054 314 781 2777 Parts Service 800 807 9054 www star mfg com...

Reviews: