background image

INSTALLATION

 

PROCEDURE

 

FOR

 

LIGHT

 

POLE:

1.

Lift

 

the

 

light

 

pole

 

into

 

position

 

over

 

the

 

installed

 

anchors

 

(refer

 

to

 

FGP

 

area

 

light

 

anchor

 

kit

 

installation

 

guide)

 

as

 

shown

 

in

 

Fig.

 

1.

  

Ensure

 

that

 

the

 

base

 

plate

 

is

 

resting

 

on

 

all

 

four

 

washers.

2.

Install

 

washers

 

and

 

hexs nut

 

as

 

shown

 

in

 

Fig.

 

2.

3.

Plumb

 

and

 

level

 

the

 

pole

 

and

 

tighten

 

all

 

anchors.

4.

Connect

 

line

in

 

wires

 

to

 

driver

 

plate

 

assembly.

 

Pass

 

wires

 

through

 

strain

 

relief.

 

See

 

Fig.

 

3.

 

Refer

 

to

 

wiring

 

diagrams

 

on

 

page

 

3.

5.

Ensure

 

that

 

the

 

wire

 

harness

 

connectors

 

are

 

pulled

 

through

 

the

 

top

 

of

 

the

 

driver

 

plate

 

assembly

 

through

 

the

 

front

 

cavity.

 

This

 

is

 

to

 

connect

 

the

 

luminaire

 

wiring.

 

6.

Gently

 

insert

 

the

 

driver

 

plate

 

assembly

 

into

 

the

 

top

 

of

 

the

 

pole.

 

Ensure

 

the

 

front

 

of

 

driver

 

plate

 

assembly

 

is

 

in

 

the

 

correct

 

orientation.

 

See

 

Fig.

 

3

 

and

 

4.

7.

Apply

 

downward

 

pressure

 

to

 

compress

 

the

 

gasket.

 

Tighten

 

the

 

six

 

hex

 

bolts

 

equally

 

using

 

a

 

13mm

 

wrench

 

until

 

snug.

 

Ensure

 

that

 

once

 

tightened,

 

the

 

driver

 

plate

 

assembly

 

rests

 

in

 

the

 

center

 

of

 

the

 

pole.

  

8.

Connect

 

luminaire

 

wiring

 

to

 

driver

 

plate

 

assembly,

 

see

 

Fig.

 

5.

9.

Gently

 

push

 

wires

 

down

 

inside

 

of

 

driver

 

plate

 

assembly.

 

Set

 

Luminaire

 

on

 

top

 

of

 

driver

 

plate

 

assembly,

 

ensuring

 

that

 

the

 

luminaire

 

mount

 

plate

 

is

 

seated

 

properly

 

on

 

the

 

top

 

of

 

the

 

driver

 

plate

 

assembly.

 

Use

 

an

 

8mm

 

hex

 

key

 

to

 

install

 

M10

 

x

 

55m

 

socket

 

head

 

cap

 

screw

 

and

 

sealing

 

washer

  

to

 

secure

 

luminaire

 

to

 

top

 

of

 

pole.

10. If

 

twist

 

lock

 

receptacle

 

is

 

specified,

 

remove

 

shorting

 

cap

 

and

 

install

 

photo

eye

 

control

 

(not

 

included),

 

see

 

Fig.6.

11. Install

 

the

 

cover

 

plate

 

as

 

shown

 

in

 

Fig.

 

7

 

and

 

8.

 

Use

 

a

 

5mm

 

hex

 

key

 

to

 

tighten

 

internal

 

socket

 

head

 

cap

 

screws

 

to

 

secure

 

the

 

two

 

halves

 

together.

Tools

 

Required

Safety

 

glasses

Wrenches,

 

1

1/4”

 

,

 

13mm

Screwdrivers,

 

Phillips

 

and

 

straight

 

blade

Wiring

 

tools

 

and

 

connectors

Proper

 

personnel,

 

crane

 

or

 

lift

 

for

 

hoisting

 

unit

 

onto

 

anchors

Level

Dimming

 

control,

 

if

 

required

Hex

 

keys,

 

8mm

 

with

 

10

12”

 

extension,

 

5mm

Twist

 

lock

 

photo

 

eye

 

control,

 

if

 

required

Landscape

 

Forms

 

is

 

not

 

responsible

 

for

 

site

 

preparation

 

and

 

footings.

  

Refer

 

to

 

the

 

installation

 

guide

 

for

 

the

 

FGP

 

light

 

anchor

 

kit

 

for

 

installing

 

the

 

anchor

 

bolts.

CAUTION!

This

 

unit

 

is

 

heavy.

 

To

 

avoid

 

injury

 

or

 

damage

 

to

 

the

 

finish,

 

we

 

recommend

 

using

 

a

 

crane

 

or

 

lift

 

for

 

hoisting

 

the

 

unit

 

onto

 

the

 

anchors.

WARNING!

Pole

 

mounted

 

luminaires

 

must

 

be

 

attached

 

either

 

before

 

or

 

immediately

after

 

pole

 

installation. Failure

 

to

 

do

 

so

 

may

 

cause

 

vibration

 

damage

 

to

 

the

 

pole

 

and

 

will

 

void

 

the

 

pole

 

warranty.

ASSEMBLE

 

WITH

 

CARE!

Pangard II

Polyester

 

Powdercoat is

 

a

 

strong,

 

long

lasting

 

finish.

  

To

 

protect

 

this

 

finish

 

during

 

assembly,

 

place

 

unwrapped

 

powdercoated parts

 

on

 

packaging

 

foam

 

or

 

other

 

non

marring

 

surface.

  

Do

 

not

 

place

 

or

 

slide

 

powdercoated parts

 

on

 

concrete

 

or

 

other

 

hard

 

or

 

textured

 

surface

 

– this

 

will

 

damage

 

the

 

finish

 

causing

 

rust

 

to

 

occur.

  

Use

 

touch

up

 

paint

 

on

 

any

 

gouges

 

in

 

the

 

finish

 

caused

 

by

 

assembly

 

tools.

Luminaire

2x

 ‐

Cover

 

plate

 

half

Twist

 

lock

 

receptacle,

optional

Installation Guide

FGP 

Area Light

www.landscapeforms.com      Ph: 800.521.2546

Date:  October 5, 2018

Page 1 of 3

Included

 

components

Shorting

 

cap

 

for

Twist

 

lock,

 

optional

Pole

Driver

 

plate

assembly

1x

 ‐

M10

 

x

 

1.5

 

x

 

55mm

 

socket

 

head

 

cap

 

screw

 

with

 

sealing

 

washer

INSTALLATION

 

PROCEDURE FOR

 

OPTIONAL

 

PHOTO

 

EYE:

Refer

 

to

 

wiring

 

diagram

 

for

 

wiring

 

details.

 

1.

Remove

 

the

 

twist

 

lock

 

cap

 

from

 

the

 

top

 

of

 

the

 

light.

 

2.

Loosen

 

the

 

two

 

phillips head

 

screws

 

two

 

turns.

IMPORTANT!

  

Do

 

not

 

remove

 

the

 

screws.

 

Loosen

 

just

 

enough

 

to

 

rotate

 

the

 

receptacle.

3.

Rotate

 

the

 

receptacle

 

until

 

the

 

arrow

 

points

 

north.

 

Tighten

 

the

 

screws.

4.

Install

 

the

 

photo

 

eye

 

(not

 

supplied

 

with

 

unit)

 

rated

 

for

 

proper

 

line

 

voltage

 

(277v,

 

1.5A).

Reviews: