Pressure loss
47/49
18
Pressure loss
Nominal flowrate
qp
Overall
length
Connection
Pressure loss
at qp
Kv-Factor
at Δp 1 bar
Graph in
diagram
m
3
/h
mm
mbar
m
3
/h
0,6
110, 190
G
3
/
4,
G 1, DN20
150
1,5
A
1,5
130, 190
G 1, DN20
160
3,8
B
1,5
110
G
3
/
4
150
3,9
C
2,5
190
G 1, DN20
210
5,3
D
2,5
130
G 1
200
5,6
E
3,5
260
G 1
1
/
4,
DN25
55
15
G
6
150
G 1
1
/
4
190
14
F
6
260
G 1
1
/
4
, DN25
140
16
H
10
200, 300
G 2, DN40
130
28
I
10
300
G 2
110
30
J
15
270
DN50
110
45
K
15
200
DN50
95
49
L
25
300
DN65
105
77
M
40
300
DN80
160
100
N
60
360
DN100
115
177
O
150
500
DN150
120
433
P
The indicated pressure loss of a flow sensor is at the nominal flowrate qp.
Using the Kv-Factor, which defines the flow rate at a pressure loss of 1 bar, the pressure loss at any given flow rate
can be calculated:
∆𝑝 = 1𝑏𝑎𝑟 × (
𝑄
𝐾
𝑣
)
2
∆𝑝 = 𝑝𝑟𝑒𝑠𝑠𝑢𝑟𝑒 𝑙𝑜𝑠𝑠 𝑖𝑛 𝑏𝑎𝑟
𝑄 = 𝑓𝑙𝑜𝑤𝑟𝑎𝑡𝑒 𝑖𝑛 𝑚³/ℎ
𝐾
𝑣
= 𝐾
𝑣
− 𝐹𝑎𝑐𝑡𝑜𝑟 𝑎𝑡 ∆𝑝 = 1 𝑏𝑎𝑟