Instantaneous values
Issue 1.2
127/143
D000058620 en a
– E470 Series 3 SMETS2 100 mm – ZCX310 – User Manual and Functional Description
© Gyr
20
Instantaneous values
The instantaneous values measured by SMETS2 E470 devices are listed in
the table below:
Measured Quantities
Resolution
Active power
P
Sum, combined
|QI+QIV|+|QII+QIII|
XXXXX.XX kW
Reactive power
Q
Sum, combined
XXXXX.XX kVAr
Apparent power
S
Sum (true RMS, S=U*I,
instantaneous value)
XXXXX.XX kVA
Power factor (only
as P/S)
1
+PF
Instantaneous
XXXX.XXX
Integration period average value
(not available to customer)
Minimum during the last billing
period (not available to
customer)
Voltage (RMS)
U
Instantaneous per phase
XXXXXX.X V
Current average over t
avr
Current (RMS)
I
Instantaneous per phase
XXXXX.XX A
Current average over t
avr
Network
frequency
fn
Instantaneous
XXXXXX.X Hz
Current average over t
avr
Table 14 Instantaneous values table
The instantaneous values are updated every second (tsampling=1sec)
Instantaneous registers are NOT settable; registers always appear as
shown in the table above. The same settings apply for showing the value
on the display or reading via communication.
All the registers can be read at any time as well as stored in various
profiles.
1
Import only. No export.