Voltage Quality Measurements
Issue 1.2
123/143
D000058620 en a
– E470 Series 3 SMETS2 100 mm – ZCX310 – User Manual and Functional Description
© Gyr
18.3 RMS Extreme Under Voltage
The meter detects when the RMS voltage falls below the RMS Extreme
Under Voltage Threshold for longer than the RMS Extreme Under Voltage
Measurement Period and, on detection:
Generates an entry in the Power Quality Event Log (0x00DD
Voltage Under 2)
If the above event is also configured in the Alarm Filter object the meter this
can be used, with a compatible external communications hub, to send an
alert to a remote Head End System.
An event is also captured in the Power Quality Event Log when the RMS
voltage rises back above the threshold.
18.4 RMS Voltage Sag Detection
The meter detects when the RMS voltage falls below the RMS Voltage Sag
Threshold for longer than the RMS Voltage Sag Measurement Period and,
on detection:
Generates an entry in the Power Quality Event Log (0x00DB
Voltage Under 1)
If the above event is also configured in the Alarm Filter object the meter this
can be used, with a compatible external communications hub, to send an
alert to a remote Head End System.
An event is also captured in the Power Quality Event Log when the RMS
voltage rises back above the threshold.
18.5 RMS Voltage Swell Detection
The meter detects when the RMS voltage rises above the RMS Voltage
Swell Threshold for longer than the RMS Voltage Sag Measurement Period
and, on detection:
Generates an entry in the Power Quality Event Log (0x00D7
Voltage Over 1)
If the above event is also configured in the Alarm Filter object the meter this
can be used, with a compatible external communications hub, to send an
alert to a remote Head End System.
An event is also captured in the Power Quality Event Log when the RMS
voltage falls back below the threshold.