Section 6: Maintenance & Lubrication
HRS3025 Hydraulic Reservoir System 316-271M
1/16/20
34
24871
24871
24873
30861
“DO NOT OVERFILL!” When checking oil, gearbox
should be oriented with flat side down as shown.
Unbolt speed pump mount from reservoir frame
and rotate gearbox down to check oil level.
Lubrication Points
25
Hours
Driveline Shaft U-Joints
Type of lubrication: Multi-purpose grease
Quantity - 4 to 8 Pumps
25
Hours
Inner Tube Bearings
Type of lubrication: Multi-purpose grease
Quantity - As Required
25
Hours
Driveline Profiles
Type of lubrication: Multi-purpose grease
Quantity - Clean & coat inner profile tube of driveline with
a light film of grease and then reassemble.
Gearbox
If oil is below bottom of site gauge/plug hole (See arrow),
remove site gauge/oil plug and add recommended gear
lube through plug hole until oil flows out of plug hole.
Reinstall and tighten site/gauge/oil plug.
Type of lubrication: 80-90W EP gear lube
Quantity = Fill until oil begins to flow out of plug hole.
NOTE:
Check oil if gearbox is leaking. Do not overfill!
Gearbox should be oriented as shown when checking
oil. Always check oil level when gearbox is cold.
As
Needed
50
Hrs
Multi-purpose
spray lube
Multi-purpose
grease lube
Multi-purpose
oil lube
Intervals in hours at which
lubrication is required
Lubrication
Legend