background image

ITEM PART NO.

DESCRIPTION

1

30-0636/02 Wrapper, External

2

51-0568

Trim, Gray

3

04-0067

Rivet

4

50-0173

Insulation, Tape, Front

5

50-0178

Insulation, Top

6

50-0214

Insulation, Tape, Sides

7

50-0118

Insulation, Tape, Back

8

04-0082

Nut, Hex, 10-24, SS

9

30-0612

Back, Plate

10 04-0477

Screw, 8 - 32 x 3/8 inch

11 42-0032

Tank, Foamed

-

42-0046

Tank, Foamed (Philippines)

12 04-0074

Nut, Clip, 10-24

13 30-0624/01 Front Support Plate
-

30-6055/01 Front Support Plate (Philippines)

14 03-0036

Clip, Over Flow

15 04-0077

Screw, #4 x 1/4 inch

16 04-0061

Screw, 8 x 1/2 inch

17 30-0115

Clip, Retaining Tube

18 04-0443

Screw, 10 - 24 x 3/8 inch

19 13-0005

Bushing

20 11-0015

Connector Housing

21 23-0389

Faucet Plate, 6V

-

23-0394

Faucet Plate, 5V

-

23-0771

Faucet Plate, 4V

22 30-6644

Splash Plate, without Logo

-

30-6644-01 Splash Plate, with Logo

23 23-0159

Cup Rest

24 54-0017

Drip Tray

25 12-0097

Key Lock Switch

26 52-0891

Harness Assy, 6V

-

52-0890

Harness Assy, 5V

-

52-0889

Harness Assy, 4V

27 51-0580

Base Assy

28 23-0831

Insulated Plate Assy

29 23-0824/01 Bonnet Assy, White
30 30-5854/01 Retainer Channel
31 04-0429

Rivet

32 04-0187

Spacer

33 30-5143

Clip, Drain

34 01-1483

Drain, Elbow Assy

35 08-0104

Drain, Tube

36 01-0450

Tube Support

37 04-0072

Rivet

NOTE: Cage Assembly Part Numbers are:

-

23-1047

4V, 4-0 Manifold, 3/8 inch Syrup Inlets

-

23-1064

5V, 2-2-1 Manifold, 3/8 inch Syrup
Inlets - High Performance

-

23-1201/02 6V, 3-2-1 Manifold, 3/8 inch Syrup

Inlets - High Performance

5.4

SERIES 1500 CABINET ASSEMBLY, HIGH PERFORMANCE (CONTINUED)

14

Summary of Contents for SERIES 1500 POSTMIX

Page 1: ...75 F 23 9 C ambient inlet water and syrup INSTALLATION AND SERVICE MANUAL FOR LANCER DISPENSERS SERIES 1500 POSTMIX SERIES 1500E POSTMIX SERIES 1500 PREMIX REV 02 11 00 P N 28 0450 This is an initial...

Page 2: ...up SPECIFICATION 1500 PREMIX DIMENSIONS Width 19 3 16 inches 48 74 cm Depth 24 inches 60 96 cm Height without legs 25 3 8 inches 64 45 cm WEIGHT Shipping 150 pounds 68 2 kg Empty 130 pounds 59 kg Oper...

Page 3: ...WILL NOT SHUT OFF 6 4 10 EXCESSIVE FOAMING 6 4 11 COMPRESSOR DOES NOT START NO HUM BUT CONDENSER FAN MOTOR RUNS 6 4 12 COMPRESSOR STARTS AND CONTINUES TO RUN UNTIL FREEZE UP AND WILL NOT CUT OFF 6 4 1...

Page 4: ...o sit on a flat supported surface capable of supporting a minimum weight of 400 pounds 182 kg It may be either counter or leg mounted A template is provided to cut and or drill the necessary holes for...

Page 5: ...e installation Approximately three 3 hours are required to form a full ice bank NOTE Units equipped with an electronic ice bank control contain a five 5 minute delay Compressor and fan motor will not...

Page 6: ...te tubing through cutout in counter or through access hole in back of unit D Leave 12 inches 30 cm of extra tubing length below the counter for servicing and moving the dispenser E Connect to appropri...

Page 7: ...t 50 PPM 50 mg L chlorine Make sure that lines are completely filled and allow to stand for 10 minutes G Reconnect syrup containers and ready Unit for operation H Draw drinks to refill lines and flush...

Page 8: ...ve syrup flow control from control upper body and clean out any foreign material to ensure smooth free spool movement 4 6 Erratic ratio A Incoming water and or syrup A Check pressure and adjust supply...

Page 9: ...rated voltage C Incorrect wiring C Refer to wiring diagram and correct D Compressor malfunctioning D Replace compressor 4 12 Compressor starts and A Ice bank control failure A Replace ice bank control...

Page 10: ...tion at PCB Off delay Lancer EIBC Export only 4 17 Compressor and A Improper Wiring A Check Power Indicator Lamp Condenser Fan Motor check wiring per Wiring Diagram will not start after B Probe unplug...

Page 11: ...OTOR WHITE BLACK GREEN KILL SWITCH JCT COMPRESSOR LANCER ICE BANK CONTROL PROBE L RELAY S M M S FAN MOTOR C OVERLOAD WHEN STARTING UNIT OR IF CURRENT IS INTERRUPTED THERE IS A FIVE 5 MINUTE DELAY BEFO...

Page 12: ...19 TO 42 TO 18 18 TO 11 28G 17 43 23 9 44 15 30 41 29G 29 32 TO 4 TO 18 5 22 40 40A 40B 12 11 14 13 20 45 31 7 8 10 21 42 24 33 34 35 36 46 47 TO KEYLOCK TO VALVES TO TRANSFORMER LOAD TO TRANSFORMER L...

Page 13: ...0433 01 Label 115V 60Hz 9W 28G 04 0059 Screw 8 36 x 0 375 29 52 1259 Agitator Motor Assy 115V 60Hz 25W 29A 91 0084 Motor Agitator 115V 60Hz 25W 29B 02 0032 Washer Rubber 1 0 Inch OD 29C 06 0633 Label...

Page 14: ...LL HOLE IMPOR TANT FILL WATER BATH UNTIL TANK OVERF LOW TUBE WATER FLOWS FROM TO TRANSFORMER LOAD TO COMPRESSOR TO TRANSFORMER LINE TO VALVES TO KEYLOCK 39 6 3 37 25 4 37 38 1 5 26 T O 3 2 2 TO 18 28A...

Page 15: ...0059 Screw 8 36 x 0 375 29 52 1259 Agitator Motor Assy 115V 60Hz 52 1379 Agitator Motor Assy 220 240V 50 60Hz 29A 91 0086 Motor Agitator 220V 50 60Hz 91 0084 Motor Agitator 115V 60Hz 29B 02 0032 Wash...

Page 16: ...3 29 2 1 32 31 7 6 11 8 9 10 27 16 33 34 23 24 22 18 20 19 21 13 15 17 15 14 12 5 37 25 26 36 35 4 6 30 28 8 5 4 SERIES 1500 CABINET ASSEMBLY HIGH PERFORMANCE 13...

Page 17: ...Housing 21 23 0389 Faucet Plate 6V 23 0394 Faucet Plate 5V 23 0771 Faucet Plate 4V 22 30 6644 Splash Plate without Logo 30 6644 01 Splash Plate with Logo 23 23 0159 Cup Rest 24 54 0017 Drip Tray 25 1...

Page 18: ...27 23 5 4 6 4 7 2 32 12 33 34 35 22 1 24 12 12 30 31 12 20 19 12 13 11 26 21 3 28 11 8 29 14 17 18 16 15 14 10 9 25 6 5 5 SERIES 1500E AND 1500 PREMIX CABINET ASSEMBLY 15...

Page 19: ...30 6644 01 Splash Plate with Logo 19 23 0159 Cup Rest 20 54 0017 Drip Tray 21 12 0097 Key Lock Switch 22 52 0891 Harness Assy 6V 52 0890 Harness Assy 5V 52 0889 Harness Assy 4V 23 23 0831 Insulator P...

Page 20: ...17 NOTES Please refer to the Lancer web site www lancercorp com for information relating to Lancer Installation and Service Manuals Instruction Sheets Technical Bulletins Service Bulletins etc...

Reviews: