INSTRUCTIONS FOR TROUBLE SHOOTING
LANCER ELECTRONIC ICE BANK CONTROL (EIBC)
FOR MODELS: DELTA/1500/800
1. To check for normal PCB operation, please refer to the following instructions.
1.1
Turn power
OFF
or ensure that power has been
disconnected
from dispenser.
1.2
Pull PCB upward, so that it is no longer connected to the terminal block.
WARNING
TERMINAL BLOCK HAS AC LINE VOLTAGE AND SHOULD BE COVERED WITH TAPE.
INSERT A SMALL STRIP OF ELECTRICAL TAPE BETWEEN BOARD AND CONNECTOR TO
PREVENT RE-CONNECTION.
TAPE SHOULD COVER BARE ELECTRICAL CONNECTIONS TO PREVENT ELECTRICAL
SHOCK.
1.3
Disconnect both the Ice Bank probe (J2) and the Carbonator probe (J3) (if equipped) connections
from board (see Figure 1 on reverse).
1.4
Use a short copper wire, paper clip, or other means to short the Ice Bank probe terminals (J2) on
the PCB by touching all three (3) pins together.
1.5
Set Ohm test meter to measure continuity.
1.6
Reconnect power or turn dispenser ON. Observe time and check continuity of the PCB edge
connector (see Figure 1 on reverse).
A. The following should be observed:
1. Terminal 3 to 2 (Carbonator): During the first 2.5 to 3.5 minutes, there should be continuity.
After 2.5 to 3.5 minutes, there should be
NO
continuity.
2. Terminal 3 to 1 (Compressor): During the first 4 to 6 minutes, there should be
NO
continu-
ity. After 4 to 6 minutes, there should be continuity. Remove wire from J2 connector. There
should be
NO
continuity from 3 to 1.
3. You should be able to hear the “click” sound of the relay closing when the time delays end.
1.7
Turn electrical power
OFF
for 15 seconds and then back
ON
again to reset Carbonator timer. Again,
measure continuity of the PCB edge connector.
A. Terminal 3 to 2: There should be continuity. Use a short copper wire, paper clip, or other means
to short the Carbonator probe terminals (J3) on the PCB by touching all three (3) pins together.
This should be done before the 2.5 to 3.5 minute time limit has elapsed. Measure the
continuity again between Terminal 3 to 2. There should be
NO
continuity.
1.8
If all the above work as noted, then the board is functioning properly. Remove tape and reconnect
board. If any non-conformities are found, the PCB must be replaced (PN 52-0952/01).
DATE: 03/18/98
P.N.:
28-0393
6655 LANCER BLVD. • SAN ANTONIO, TEXAS 78219 USA • (210) 310-7000
FAX SALES
• USA -CANADA – 210-310-7250 • LATIN AMERICA – 210-310-7245 • ASIA – 210-310-7242 •
• EUROPE – 32-2-755-2399 • PACIFIC – 61-8-8268-1978 •
FAX ENGINEERING: • 210-310-7096
"Lancer" is the registered trademark of Lancer • Copyright — 1998 by Lancer, all rights reserved.