3.
Remove the diffuser by pulling down.
4.
Install Lancer yellow syrup separator (PN 54-0031) in place of the nozzle.
5.
Activate the dispensing valve to fill the separator syrup tube.
6.
Hold a brix cup under the syrup separator and dispense water and syrup into the cup for four seconds. Divide
the number of ounces (ml) of water in the cup by four to determine the water flow rate per second.
7.
To obtain the proper flow, use a screwdriver to adjust the water flow control.
8.
Repeat process for each valve.
1.9 ADJUSTING WATER TO SYRUP RATIO (BRIX) FOR LEV
1.
Hold the brix cup under the syrup separator and activate valve. Check ratio (brix).
2.
To obtain the proper ratio, use screwdriver to adjust syrup flow control.
3.
Remove syrup separator.
4.
Install diffuser and nozzle.
5.
Slide ID panel DOWN.
6.
Repeat process for each valve.
2. MVU OPERATION
2.1 MVU PLUMBING DIAGRAM - MAKING CONNECTIONS TO THE MVU
1.
Positions A and F are ambient syrups only. Remove the rear cover to make these syrup connections. All other
syrups and water are fed through the cold plate connections at the front of the unit. Plumb according to the
label on the unit.
Soda/Water
Flow Controls
and Solenoids